P055 Mystic rupter of the large anterior comunicate aneurysm 1 year after the treatment with low-profile flow diverter stent, with no evidence of the sacc perfusion on the follow up imaging

<h3>Introduction</h3> Wide neck aneurysm of the anterior communicating artery frequently involving A1-2 angle are challenging cases for the surgery and endovascular treatment (EVT). The availability of low-profile flow-diverter stents nowadays enables EVT of intracranial aneurysms beyond the circle of Wills. <h3>Case Description</h3> 67 years old male patient (Pt.) with occasional large asymptomatic anterior communicant aneurysm, mostly thrombosed, was candidate for EVT with low-profile flow diverter stent under double antiplatelet therapy preparation. Although the presence of advanced atherosclerotic disease the stent was easily deployed from A2 to A1 ipsilateral segment with complete aneurysm exclusion and minimal contrast media stagnation in it. After the procedure, Heubner artery occlusion was observed, in correlation with complex clinical situation, while ischemia of head of the caudate nucleus on CT imaging was diagnosed. <h3>Results</h3> Good clinical improvement was osberved on the follow up (FU). Treated aneurysm was occluded on 1-month CT imaging, with a minimal increase of the diameter 19mm versus 14mm before the treatment. No contrast impregnation of aneurysm wall neither aneurysm sacc perfusion was observed on 3-month magnetic resonance with contrast media FU. 12-months after the treatment Pt. was hospitalized for subarachnoid hemorrhage due to aneurysm rupture with no evidence of sacc perfusion on the angiography control that was mandatory before the surgery treatment.

Authors

Institutions

Publication Details

Journal
Abstracts
Published
2024-09-01
DOI
https://doi.org/10.1136/jnis-2024-esmint.92
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P055 Mystic rupter of the large anterior comunicate aneurysm 1 year after the treatment with low-profile flow diverter stent, with no evidence of the sacc perfusion on the follow up imaging

Annarita Dapoto, Massimo Sponza, Vladimir Gavrilovic
Abstracts
Intracranial Aneurysms: Treatment and Complications
article

P055 Mystic rupter of the large anterior comunicate aneurysm 1 year after the treatment with low-profile flow diverter stent, with no evidence of the sacc perfusion on the follow up imaging

Annarita Dapoto, Massimo Sponza, Vladimir Gavrilovic
article en

Abstract

<h3>Introduction</h3> Wide neck aneurysm of the anterior communicating artery frequently involving A1-2 angle are challenging cases for the surgery and endovascular treatment (EVT). The availability of low-profile flow-diverter stents nowadays enables EVT of intracranial aneurysms beyond the circle of Wills. <h3>Case Description</h3> 67 years old male patient (Pt.) with occasional large asymptomatic anterior communicant aneurysm, mostly thrombosed, was candidate for EVT with low-profile flow diverter stent under double antiplatelet therapy preparation. Although the presence of advanced atherosclerotic disease the stent was easily deployed from A2 to A1 ipsilateral segment with complete aneurysm exclusion and minimal contrast media stagnation in it. After the procedure, Heubner artery occlusion was observed, in correlation with complex clinical situation, while ischemia of head of the caudate nucleus on CT imaging was diagnosed. <h3>Results</h3> Good clinical improvement was osberved on the follow up (FU). Treated aneurysm was occluded on 1-month CT imaging, with a minimal increase of the diameter 19mm versus 14mm before the treatment. No contrast impregnation of aneurysm wall neither aneurysm sacc perfusion was observed on 3-month magnetic resonance with contrast media FU. 12-months after the treatment Pt. was hospitalized for subarachnoid hemorrhage due to aneurysm rupture with no evidence of sacc perfusion on the angiography control that was mandatory before the surgery treatment.

Abstracts
University of Udine (IT), Friuli Innovazione (Italy) (IT), International Centre for Mechanical Sciences (IT)
Openalex Percentile: Top 77%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.