P100 Structural mechanic characteristics of stable cerebral aneurysms

<h3>Introduction</h3> Stable cerebral aneurysms are assumed to be aneurysms without any significant geometric change over the period of at least three subsequent yearly checkups. Many studies using computational fluid dynamics have been able to demonstrate hemodynamic differences between ruptured and unruptured aneurysms. Although dynamic simulations including complex flow models have already been performed, there are only a few computational studies focusing on the structural mechanics of cerebral aneurysms. <h3>Aim of Study</h3> The aim of this study is to show characteristic scenarios for stable aneurysms for correct identification during regular checkups. <h3>Methods</h3> Stable cerebral aneurysms were analyzed with Fluid-Structure Interaction simulations identifying scenarios in the structural mechanic behavior. Digital subtraction angiography images, computed tomography angiography images and magnetic resonance angiography images of nineteen patients were transferred into geometric format for the simulations including fluid mechanics of the blood flow and structural mechanics of the wall. For data evaluation solely Mises stress values from the structural results were taken. <h3>Results</h3> Two scenarios were identified in the wall stress distribution of stable cerebral aneurysms. In one scenario, two distinct high stress regions can be identified on the sides of the aneurysms, whereas in the second scenario, high stress regions can be located at arbitrary positions on the aneurysm. Additionally, statistical evaluation shows a significant difference (p=0.0014) in Mises stress between the two scenarios. Wall stress may be taken as indicator for different behavior patterns. <h3>Conclusion</h3> In this work, we were able to show structural mechanic behavior of stable cerebral aneurysms with the help of Fluid-Structure interaction simulations. <h3>Disclosure of Interest</h3> no.

Authors

Institutions

Publication Details

Journal
Abstracts
Published
2024-09-01
DOI
https://doi.org/10.1136/jnis-2024-esmint.136
Primary Topic
Elasticity and Material Modeling
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P100 Structural mechanic characteristics of stable cerebral aneurysms

Zoltán Major, Matthias Gmeiner, Michael Giretzlehner, Wolfgang Fenz et al.
1 links
Abstracts
Elasticity and Material Modeling
article

P100 Structural mechanic characteristics of stable cerebral aneurysms

Zoltán Major, Matthias Gmeiner, Michael Giretzlehner, Wolfgang Fenz, Stefan Thumfart, Nico Stroh, József Nagy, Andreas Gruber, Julia Maier
article en

Abstract

<h3>Introduction</h3> Stable cerebral aneurysms are assumed to be aneurysms without any significant geometric change over the period of at least three subsequent yearly checkups. Many studies using computational fluid dynamics have been able to demonstrate hemodynamic differences between ruptured and unruptured aneurysms. Although dynamic simulations including complex flow models have already been performed, there are only a few computational studies focusing on the structural mechanics of cerebral aneurysms. <h3>Aim of Study</h3> The aim of this study is to show characteristic scenarios for stable aneurysms for correct identification during regular checkups. <h3>Methods</h3> Stable cerebral aneurysms were analyzed with Fluid-Structure Interaction simulations identifying scenarios in the structural mechanic behavior. Digital subtraction angiography images, computed tomography angiography images and magnetic resonance angiography images of nineteen patients were transferred into geometric format for the simulations including fluid mechanics of the blood flow and structural mechanics of the wall. For data evaluation solely Mises stress values from the structural results were taken. <h3>Results</h3> Two scenarios were identified in the wall stress distribution of stable cerebral aneurysms. In one scenario, two distinct high stress regions can be identified on the sides of the aneurysms, whereas in the second scenario, high stress regions can be located at arbitrary positions on the aneurysm. Additionally, statistical evaluation shows a significant difference (p=0.0014) in Mises stress between the two scenarios. Wall stress may be taken as indicator for different behavior patterns. <h3>Conclusion</h3> In this work, we were able to show structural mechanic behavior of stable cerebral aneurysms with the help of Fluid-Structure interaction simulations. <h3>Disclosure of Interest</h3> no.

Abstracts
Johannes Kepler University of Linz (AT), Upper Austrian Research (AT), Kepler Universitätsklinikum (AT), RISC Software (Austria) (AT)
Zero hunger
Openalex Percentile: Top 87%
Elasticity and Material Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.