P088 Efficacy and safety of hydrophilic polymer coated devices with prasugrel as a single antiplatelet therapy in the treatment in patients with acutely ruptured intracranial aneurysms

<h3>Introduction</h3> Here, we report our experience in using hydrophilic polymer-coated (HPC) Devices with prasugrel as single antiplatelet therapy (SAPT) to treat patients with subarachnoid hemorrhage (SAH) in the acute setting. <h3>Aim of Study</h3> The objective of this study is to assess the safety and efficacy of HPC-coated devices with prasugrel as SAPT in the treatment of SAH patients. <h3>Methods</h3> Patients treated within 30 days after SAH with a p64/p48 MW HPC FDs, pEGASUS or pCONUS 2-HPC (Wallaby Medical Phenox) were prospectively identified. Outcomes, intraprocedural and postprocedural complications, and mid-term follow-up were evaluated. <h3>Results</h3> A total of 55 patients (51% women; mean age 52 years) were treated in 58 sessions using 78 devices (p64 MW HPC: 39; p48 MW HPC: 31; pEGASUS: 6; pCONUS 2-HPC: 2). Two patients (3,6%) experienced FD-dependent ischaemic complications. No intraprocedural thromboembolic complications were documented. No cases of aneurysm rerupture or hemorrhagic complications related to antiplatelet therapy were recorded. Three patients exhibited mild, non-haemodynamically relevant intimal hyperplasia in the mid-term control. No devices demonstrated in-stent stenosis or occlusion. <h3>Conclusion</h3> The utilisation of HPC-coated devices with prasugrel as SAPT is both safe and efficacious in the treatment of patients with acutely ruptured aneurysms. It is essential to manage SAPT with prasugrel adequately, particularly through the utilisation of higher than usual doses and the performance of daily efficacy testing, in order to prevent the occurrence of ischaemic and thromboembolic complications. <h3>Disclosure of Interest</h3> no.

Authors

Institutions

Publication Details

Journal
Abstracts
Published
2024-09-01
DOI
https://doi.org/10.1136/jnis-2024-esmint.124
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P088 Efficacy and safety of hydrophilic polymer coated devices with prasugrel as a single antiplatelet therapy in the treatment in patients with acutely ruptured intracranial aneurysms

Alexandru Cimpoca, Oliver Ganslandt, Kamran Hajiyev, Von Gottberg Philipp et al.
Abstracts
Acute Ischemic Stroke Management
article

P088 Efficacy and safety of hydrophilic polymer coated devices with prasugrel as a single antiplatelet therapy in the treatment in patients with acutely ruptured intracranial aneurysms

Alexandru Cimpoca, Oliver Ganslandt, Kamran Hajiyev, Von Gottberg Philipp, Ali Khanafer, Hans H. Henkes
article en

Abstract

<h3>Introduction</h3> Here, we report our experience in using hydrophilic polymer-coated (HPC) Devices with prasugrel as single antiplatelet therapy (SAPT) to treat patients with subarachnoid hemorrhage (SAH) in the acute setting. <h3>Aim of Study</h3> The objective of this study is to assess the safety and efficacy of HPC-coated devices with prasugrel as SAPT in the treatment of SAH patients. <h3>Methods</h3> Patients treated within 30 days after SAH with a p64/p48 MW HPC FDs, pEGASUS or pCONUS 2-HPC (Wallaby Medical Phenox) were prospectively identified. Outcomes, intraprocedural and postprocedural complications, and mid-term follow-up were evaluated. <h3>Results</h3> A total of 55 patients (51% women; mean age 52 years) were treated in 58 sessions using 78 devices (p64 MW HPC: 39; p48 MW HPC: 31; pEGASUS: 6; pCONUS 2-HPC: 2). Two patients (3,6%) experienced FD-dependent ischaemic complications. No intraprocedural thromboembolic complications were documented. No cases of aneurysm rerupture or hemorrhagic complications related to antiplatelet therapy were recorded. Three patients exhibited mild, non-haemodynamically relevant intimal hyperplasia in the mid-term control. No devices demonstrated in-stent stenosis or occlusion. <h3>Conclusion</h3> The utilisation of HPC-coated devices with prasugrel as SAPT is both safe and efficacious in the treatment of patients with acutely ruptured aneurysms. It is essential to manage SAPT with prasugrel adequately, particularly through the utilisation of higher than usual doses and the performance of daily efficacy testing, in order to prevent the occurrence of ischaemic and thromboembolic complications. <h3>Disclosure of Interest</h3> no.

Abstracts
Klinikum Stuttgart (DE)
Openalex Percentile: Top 78%
Acute Ischemic Stroke Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.