P118 The iNstroke thromboaspiration catheter in acute ischemic stroke—A single-center prospective study

<h3>Introduction</h3> The iNstroke aspiration thrombus extraction device by iVascular is a single-lumen device (0.71’) with variable stiffness form proximal to distal designed to extract emboli and thrombi from neurovascular blood vessels. <h3>Aim of Study</h3> The aim of this study was to evaluate the efficacy and safety of the iNstroke aspiration device in mechanical thrombectomy for patients presenting with acute ischemic stroke due to large vessel occlusion within 24 hours from symptom onset. <h3>Methods</h3> ASPIC-01 is a prospective, single-site, clinical trial. Efficacy endpoints: successful recanalization (mTICI≥2b) and mRS 0-2 at 90 days. Safety endpoints: combined serious adverse events (SAE) at 24 hours and all-cause mortality at 90 days. The intention-to-treat (ITT) set included all subjects meeting inclusion criteria. The device implant population included all subjects in whom only iNstroke was used. An interim analysis was performed in 48 patients. <h3>Results</h3> Mean age: 70.3 ± 12.3 years, 62.5% male. Baseline: NIHSS median 19.5 [13.0-25.0], ASPECTS median 9.0 [7.0-10.0]. In ITT: recanalization 68.8% (95% CI 53.8-81.3), 90-day mRS 0-2 62.5% (95% CI 47.4-76.1%). Device implant population: recanalization 100% (95% CI 87.2-100.0), 90-day mRS 0-2 63% (95% CI 42.4-80.6%). No SAEs related to the device were reported. All-cause mortality rate at 90 days was 14.6% (95% CI 6.1-27.8%). <h3>Conclusion</h3> The iNstroke aspiration device represents a safe and effective option for performing neurothrombectomy using primary aspiration, with a high recanalization rate observed in selected cases. <h3>Disclosure of Interest</h3> no.

Authors

Institutions

Publication Details

Journal
Abstracts
Published
2024-09-01
DOI
https://doi.org/10.1136/jnis-2024-esmint.154
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P118 The iNstroke thromboaspiration catheter in acute ischemic stroke—A single-center prospective study

Alejandro González, Aynara Zamora, Elena Zapata‐Arriaza, Sara Pich et al.
Abstracts
Acute Ischemic Stroke Management
article

P118 The iNstroke thromboaspiration catheter in acute ischemic stroke—A single-center prospective study

Alejandro González, Aynara Zamora, Elena Zapata‐Arriaza, Sara Pich, Marta Aguilar Gil, Asier de Albóniga, Carla Agustí
article en

Abstract

<h3>Introduction</h3> The iNstroke aspiration thrombus extraction device by iVascular is a single-lumen device (0.71’) with variable stiffness form proximal to distal designed to extract emboli and thrombi from neurovascular blood vessels. <h3>Aim of Study</h3> The aim of this study was to evaluate the efficacy and safety of the iNstroke aspiration device in mechanical thrombectomy for patients presenting with acute ischemic stroke due to large vessel occlusion within 24 hours from symptom onset. <h3>Methods</h3> ASPIC-01 is a prospective, single-site, clinical trial. Efficacy endpoints: successful recanalization (mTICI≥2b) and mRS 0-2 at 90 days. Safety endpoints: combined serious adverse events (SAE) at 24 hours and all-cause mortality at 90 days. The intention-to-treat (ITT) set included all subjects meeting inclusion criteria. The device implant population included all subjects in whom only iNstroke was used. An interim analysis was performed in 48 patients. <h3>Results</h3> Mean age: 70.3 ± 12.3 years, 62.5% male. Baseline: NIHSS median 19.5 [13.0-25.0], ASPECTS median 9.0 [7.0-10.0]. In ITT: recanalization 68.8% (95% CI 53.8-81.3), 90-day mRS 0-2 62.5% (95% CI 47.4-76.1%). Device implant population: recanalization 100% (95% CI 87.2-100.0), 90-day mRS 0-2 63% (95% CI 42.4-80.6%). No SAEs related to the device were reported. All-cause mortality rate at 90 days was 14.6% (95% CI 6.1-27.8%). <h3>Conclusion</h3> The iNstroke aspiration device represents a safe and effective option for performing neurothrombectomy using primary aspiration, with a high recanalization rate observed in selected cases. <h3>Disclosure of Interest</h3> no.

Abstracts
Barcelona IVI Clinic (ES), Hospital Universitario Virgen del Rocío (ES)
Openalex Percentile: Top 78%
Acute Ischemic Stroke Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

P118 The iNstroke thromboaspiration catheter in acute ischemic stroke—A single-center prospective study — Alejandro González, Aynara Zamora, et al. · Abstracts (2024) | TGRS Research Map | TGRS