In-Vivo MRI in Rodents

Magnetic resonance imaging (MRI) is a potentially powerful novel peripheral nerve diagnosis technique. To determine its validity, in-vivo preclinical studies are necessary. However, when using a rodent model, positioning rats and achieving high-resolution images can be challenging. We present a short report that outlines an optimal protocol for positioning rats for in-vivo MRI acquisition. Female Sprague-Dawley rats with sciatic nerve injury were induced into anesthesia using 4% isoflurane in oxygen and maintained at 1.5%. Rats were placed into a plexiglass cradle in a right lateral recumbent position, and a surface coil was placed over the left leg. Respiration rate and body temperature were monitored throughout the scan. Our protocol was successful as rats were able to undergo MRI scanning safely and efficiently. There were no adverse reactions, and clear images of the left sciatic nerve were obtained. Animal positioning took 30 minutes, and 5 different acquisitions were obtained in 2 hours. The total time from anesthesia induction to recovery was under 3 hours. Given the increasing interest in MRI diagnostic techniques, we hope this report aids other researchers studying peripheral nerve injury imaging in rat models.

Authors

Institutions

Publication Details

Journal
Annals of Plastic Surgery
Published
2024-09-01
DOI
https://doi.org/10.1097/sap.0000000000004097
Citations
1
Primary Topic
Peripheral Nerve Disorders
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-Vivo MRI in Rodents

Sara C. Chaker, Mariam Saad, Yan Ling, Ya‐Ching Hung et al.
1 citations
Annals of Plastic Surgery
Peripheral Nerve Disorders
0.40
article

In-Vivo MRI in Rodents

Sara C. Chaker, Mariam Saad, Yan Ling, Ya‐Ching Hung, Isaac V. Manzanera Esteve, Wesley P. Thayer, Andrew James
article en
1 citations

Abstract

Magnetic resonance imaging (MRI) is a potentially powerful novel peripheral nerve diagnosis technique. To determine its validity, in-vivo preclinical studies are necessary. However, when using a rodent model, positioning rats and achieving high-resolution images can be challenging. We present a short report that outlines an optimal protocol for positioning rats for in-vivo MRI acquisition. Female Sprague-Dawley rats with sciatic nerve injury were induced into anesthesia using 4% isoflurane in oxygen and maintained at 1.5%. Rats were placed into a plexiglass cradle in a right lateral recumbent position, and a surface coil was placed over the left leg. Respiration rate and body temperature were monitored throughout the scan. Our protocol was successful as rats were able to undergo MRI scanning safely and efficiently. There were no adverse reactions, and clear images of the left sciatic nerve were obtained. Animal positioning took 30 minutes, and 5 different acquisitions were obtained in 2 hours. The total time from anesthesia induction to recovery was under 3 hours. Given the increasing interest in MRI diagnostic techniques, we hope this report aids other researchers studying peripheral nerve injury imaging in rat models.

Annals of Plastic SurgeryVol. 93(3S)
Sinai Hospital (US), Vanderbilt University Medical Center (US)
Good health and well-being
Openalex Percentile: Top 35%
Peripheral Nerve Disorders
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.