[Measurement and evaluation of personal attenuation rating before and after the training of the noise-exposed workers wearing foam earplugs].

<b>Objective:</b> To measure and compare the difference of personal attenuation rating (PAR) of the workers wearing foam earplugs before and after the training, and to evaluate the effect of ear protector wearing training on the noise protection. <b>Methods:</b> In February 2023, 94 workers exposed to noise in a machinery manufacturing factory were selected as subjects. The production noise in the workplace was measured and subjects were trained to wear earplugs. The PAR values of wearing 3M 1110 foam test earplugs were measured and recorded before and after the training by using the fit testing of hearing protection device. The differences between the actual PAR values with nominal values and the noise attenuation values in related standards were compared, and the protective effect of hearing protection device before and after training was evaluated. <b>Results:</b> The average age of the subjects was (36.76±11.48) years old, the average length of service was (16.34±11.64) years, and the average exposure time to noise was (15.67±11.64) years. The noise detection results of the subjects' posts were ranged from 80.1 to 94.3 dB (A). The results of subjects wore 3M 1110 foam test earplugs for fit testing showed that the binaural PAR value after training was (19.3±6.4) dB (A), which was significantly higher than that before training (11.1±7.4) dB (A) (<i>t</i>=13.31, <i>P</i><0.001). After training, 11 people (11.70%) could reach the corrected noise reduction value (NRR value), 26 people (27.66%) could reach the standard of single noise reduction value (SNR value) ×0.6, and 84 people (89.36%) could reach the standard of (NRR-7) /2. The under protection rate of hearing protectors after training (7.45%) was significantly lower than that before training (45.74%), and the difference of different protection levels before and after training was statistically significant (χ(2)=40.83, <i>P</i><0.001) . <b>Conclusion:</b> It is suggested that enterprises should use the fit testing instead of nominal value estimation to evaluate the noise reduction effect of hearing protection device. Special training on the selection and use of hearing protection device should be strengthened, so as to ensure that workers wear them correctly and improve the protective effect of hearing protection device.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2024-08-20
DOI
https://doi.org/10.3760/cma.j.cn121094-20230817-00033
Primary Topic
Noise Effects and Management
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Measurement and evaluation of personal attenuation rating before and after the training of the noise-exposed workers wearing foam earplugs].

Yang Bao, Lili Pan, Jing Liu, Ruisheng Zhang et al.
PubMed
Noise Effects and Management
article

[Measurement and evaluation of personal attenuation rating before and after the training of the noise-exposed workers wearing foam earplugs].

Yang Bao, Lili Pan, Jing Liu, Ruisheng Zhang, Kedan Gu, Xinyue Wang
article en

Abstract

<b>Objective:</b> To measure and compare the difference of personal attenuation rating (PAR) of the workers wearing foam earplugs before and after the training, and to evaluate the effect of ear protector wearing training on the noise protection. <b>Methods:</b> In February 2023, 94 workers exposed to noise in a machinery manufacturing factory were selected as subjects. The production noise in the workplace was measured and subjects were trained to wear earplugs. The PAR values of wearing 3M 1110 foam test earplugs were measured and recorded before and after the training by using the fit testing of hearing protection device. The differences between the actual PAR values with nominal values and the noise attenuation values in related standards were compared, and the protective effect of hearing protection device before and after training was evaluated. <b>Results:</b> The average age of the subjects was (36.76±11.48) years old, the average length of service was (16.34±11.64) years, and the average exposure time to noise was (15.67±11.64) years. The noise detection results of the subjects' posts were ranged from 80.1 to 94.3 dB (A). The results of subjects wore 3M 1110 foam test earplugs for fit testing showed that the binaural PAR value after training was (19.3±6.4) dB (A), which was significantly higher than that before training (11.1±7.4) dB (A) (<i>t</i>=13.31, <i>P</i><0.001). After training, 11 people (11.70%) could reach the corrected noise reduction value (NRR value), 26 people (27.66%) could reach the standard of single noise reduction value (SNR value) ×0.6, and 84 people (89.36%) could reach the standard of (NRR-7) /2. The under protection rate of hearing protectors after training (7.45%) was significantly lower than that before training (45.74%), and the difference of different protection levels before and after training was statistically significant (χ(2)=40.83, <i>P</i><0.001) . <b>Conclusion:</b> It is suggested that enterprises should use the fit testing instead of nominal value estimation to evaluate the noise reduction effect of hearing protection device. Special training on the selection and use of hearing protection device should be strengthened, so as to ensure that workers wear them correctly and improve the protective effect of hearing protection device.

PubMedVol. 42(8)
Wuhan Prevention and Treatment Center for Occupational Diseases (CN), Nanjing Municipal Center for Disease Control And Prevention (CN)
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.