Active constraint control for the surgical robotic platform with concentric connector joints

Robotic minimally invasive surgery (MIS) has changed numerous surgical techniques in the past few years and enhanced their results. Haptic feedback is integrated into robotic surgical systems to restore the surgeon's perception of forces in response to interaction with objects in the surgical environment. The ideal exact emulation of the robot's interaction with its physical environment in free space is a very challenging problem to solve completely. Previously, we introduced the surgical robotic platform (SRP) with a novel concentric connector joint (CCJ). This study aims to develop a haptic control system that integrates an active constraint controller into a surgical robot platform. We have successfully established haptic feedback control for the surgical robot using constraint control and inverse kinematic relationships integrated into the overall positioning structure. A preliminary feasibility study, modelling, and simulation were presented.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2024-09-02
DOI
https://doi.org/10.1016/j.medengphy.2024.104236
Citations
1
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Active constraint control for the surgical robotic platform with concentric connector joints

Samir Morad, Ravi Vaidyanathan, Christian Ulbricht, Paul Harkin et al.
1 citations
Medical Engineering & Physics
Soft Robotics and Applications
0.18
article

Active constraint control for the surgical robotic platform with concentric connector joints

Samir Morad, Ravi Vaidyanathan, Christian Ulbricht, Paul Harkin, Kim H. Parker, Justin Chan
article en
1 citations

Abstract

Robotic minimally invasive surgery (MIS) has changed numerous surgical techniques in the past few years and enhanced their results. Haptic feedback is integrated into robotic surgical systems to restore the surgeon's perception of forces in response to interaction with objects in the surgical environment. The ideal exact emulation of the robot's interaction with its physical environment in free space is a very challenging problem to solve completely. Previously, we introduced the surgical robotic platform (SRP) with a novel concentric connector joint (CCJ). This study aims to develop a haptic control system that integrates an active constraint controller into a surgical robot platform. We have successfully established haptic feedback control for the surgical robot using constraint control and inverse kinematic relationships integrated into the overall positioning structure. A preliminary feasibility study, modelling, and simulation were presented.

Medical Engineering & PhysicsVol. 132(1)
University of London (GB), University of East London (GB), Charing Cross Hospital (GB), University College London (GB), Imperial College London (GB)
University of East London, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 53%
Soft Robotics and Applications
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.