Comparative Analysis of Cooling Load Calculations: CLTD Method vs. Carrier HAP 5.01 Software for Hotel HVAC Design

This study examines the cooling load requirements of a hotel building by comparing two methodologies: the traditional Cooling Load Temperature Difference (CLTD) method and the Carrier Hourly Analysis Program (HAP) 5.01 software. The primary objective is to validate the accuracy and reliability of these methods in calculating cooling loads across different room types, from standard rooms to larger, more complex suites. The results show that the CLTD method consistently yields higher cooling load estimates, with discrepancies ranging from 3% to 14% compared to HAP 5.01 calculations. These differences are most significant in larger rooms, such as suites and owner’s suites, which have more extensive glass areas, higher occupancy, and more heat-generating equipment. The findings indicate that while the CLTD method is valuable for quick, preliminary estimates, the HAP 5.01 software provides a more precise and comprehensive analysis, taking into account hourly variations, equipment schedules, and other factors that impact cooling loads. This research highlights the need for careful selection of the appropriate calculation method to ensure the efficient design of HVAC systems, maximizing energy efficiency, and maintaining occupant comfort. The study concludes that for projects requiring high accuracy, particularly in complex or large spaces, dynamic simulation tools like HAP 5.01 are preferable. Detailed cooling load results and comparisons are provided in the supplementary documentation, offering further insights into the analysis and its implications for HVAC design.

Authors

Institutions

Publication Details

Journal
International Journal of Innovation in Mechanical Engineering and Advanced Materials
Published
2024-09-01
DOI
https://doi.org/10.22441/ijimeam.v6i1.23781
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Cooling Load Calculations: CLTD Method vs. Carrier HAP 5.01 Software for Hotel HVAC Design

Komarudin Komarudin, Madarif Prawibowo
International Journal of Innovation in Mechanical Engineering and Advanced Materials
Building Energy and Comfort Optimization
article

Comparative Analysis of Cooling Load Calculations: CLTD Method vs. Carrier HAP 5.01 Software for Hotel HVAC Design

Komarudin Komarudin, Madarif Prawibowo
article en

Abstract

This study examines the cooling load requirements of a hotel building by comparing two methodologies: the traditional Cooling Load Temperature Difference (CLTD) method and the Carrier Hourly Analysis Program (HAP) 5.01 software. The primary objective is to validate the accuracy and reliability of these methods in calculating cooling loads across different room types, from standard rooms to larger, more complex suites. The results show that the CLTD method consistently yields higher cooling load estimates, with discrepancies ranging from 3% to 14% compared to HAP 5.01 calculations. These differences are most significant in larger rooms, such as suites and owner’s suites, which have more extensive glass areas, higher occupancy, and more heat-generating equipment. The findings indicate that while the CLTD method is valuable for quick, preliminary estimates, the HAP 5.01 software provides a more precise and comprehensive analysis, taking into account hourly variations, equipment schedules, and other factors that impact cooling loads. This research highlights the need for careful selection of the appropriate calculation method to ensure the efficient design of HVAC systems, maximizing energy efficiency, and maintaining occupant comfort. The study concludes that for projects requiring high accuracy, particularly in complex or large spaces, dynamic simulation tools like HAP 5.01 are preferable. Detailed cooling load results and comparisons are provided in the supplementary documentation, offering further insights into the analysis and its implications for HVAC design.

International Journal of Innovation in Mechanical Engineering and Advanced MaterialsVol. 6(1)
Universitas Dian Nusantara (ID)
Affordable and clean energy
Openalex Percentile: Top 85%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.