The Application of Amplitude Variation with Frequency (AVF) Seismic Attribute to Map Gas Saturation Values in low Impedance Sandstone Reservoirs

This paper discusses an approach to apply Amplitude Variation with Frequency (AVF) attributes for identifying and mapping gas-saturation values (Sg) in low impedance sand reservoirs. Rock-physics modelling and analyses were done prior to application of the approach to the log and seismic data in the Sadewa field, Kutai Basin, Kalimantan, Indonesia. Cross-plot sensitivity analysis shows that the AV F attribute derived from near-angle stacked seismic data is correlated linearly to the gas saturation value with correlation coefficient 0.94. Comparison of AVO-based density and AVF-based gas saturation (Sg) maps show that the density map can give sand distribution, but not the gas saturation, as the density is affected by lithology and porosity. On the other hand, the AV F map can show gas saturation distribution, but not the lithology and porosity. Therefore, the density and AV F maps should be combined to get the complete distribution of lithology, porosity and gas saturation.

Authors

Institutions

Publication Details

Journal
First Break
Published
2024-09-01
DOI
https://doi.org/10.3997/1365-2397.fb2024080
Primary Topic
Seismic Imaging and Inversion Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Application of Amplitude Variation with Frequency (AVF) Seismic Attribute to Map Gas Saturation Values in low Impedance Sandstone Reservoirs

Erlangga Septama, Wahyu Triyoso, Sigit Sukmono, Pongga Dikdya Wardaya et al.
First Break
Seismic Imaging and Inversion Techniques
article

The Application of Amplitude Variation with Frequency (AVF) Seismic Attribute to Map Gas Saturation Values in low Impedance Sandstone Reservoirs

Erlangga Septama, Wahyu Triyoso, Sigit Sukmono, Pongga Dikdya Wardaya, Mokhammad Puput Erlangga, Fatkhan
article en

Abstract

This paper discusses an approach to apply Amplitude Variation with Frequency (AVF) attributes for identifying and mapping gas-saturation values (Sg) in low impedance sand reservoirs. Rock-physics modelling and analyses were done prior to application of the approach to the log and seismic data in the Sadewa field, Kutai Basin, Kalimantan, Indonesia. Cross-plot sensitivity analysis shows that the AV F attribute derived from near-angle stacked seismic data is correlated linearly to the gas saturation value with correlation coefficient 0.94. Comparison of AVO-based density and AVF-based gas saturation (Sg) maps show that the density map can give sand distribution, but not the gas saturation, as the density is affected by lithology and porosity. On the other hand, the AV F map can show gas saturation distribution, but not the lithology and porosity. Therefore, the density and AV F maps should be combined to get the complete distribution of lithology, porosity and gas saturation.

First BreakVol. 42(9)
Bandung Institute of Technology (ID), Pertamina (Indonesia) (ID), Sumatera Institute of Technology (ID)
Climate action
Openalex Percentile: Top 84%
Seismic Imaging and Inversion Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.