Prediction of ionospheric TEC during the occurrence of earthquakes in Indonesia using ARMA and CoK models

Predicting ionospheric Total Electron Content (TEC) variations associated with seismic activity is crucial for mitigating potential disruptions in communication networks, particularly during earthquakes. This research investigates applying two modelling techniques, Autoregressive Moving Average (ARMA) and Cokriging (CoK) based models to forecast ionospheric TEC changes linked to seismic events in Indonesia. The study focuses on two significant earthquakes: the December 2004 Sumatra earthquake and the August 2012 Sulawesi earthquake. GPS TEC data from a BAKO station near Indonesia and solar and geomagnetic data were utilized to assess the causes of TEC variations. The December 2004 Sumatra earthquake, registering a magnitude of 9.1–9.3, exhibited notable TEC variations 5 days before the event. Analysis revealed that the TEC variations were weakly linked to solar and geomagnetic activities. Both ARMA and CoK models were employed to predict TEC variations during the Earthquakes. The ARMA model demonstrated a maximum TEC prediction of 50.92 TECU and a Root Mean Square Error (RMSE) value of 6.15, while the CoK model predicted a maximum TEC of 50.68 TECU with an RMSE value of 6.14. The August 2012 Sulawesi earthquake having a magnitude of 6.6, revealed TEC anomalies 6 days before the event. For both the Sumatra and Sulawesi earthquakes, the GPS TEC variations showed weak associations with solar and geomagnetic activities but stronger correlations with the earthquake-induced electric field for the considered two stations. The ARMA model predicted a maximum TEC of 54.43 TECU with an RMSE of 3.05, while the CoK model predicted a maximum TEC of 52.90 TECU with an RMSE of 7.35. Evaluation metrics including RMSE, Mean Absolute Deviation (MAD), Relative Error, and Normalized RMSE (NRMSE) were employed to assess the accuracy and reliability of the prediction models. The results indicated that while both models captured the general trend in TEC variations, nuances emerged in their responses to seismic events. The ARMA model demonstrated heightened sensitivity to seismic disturbances, particularly evident on the day of the earthquake, whereas the CoK model exhibited more consistent performance across pre- and post-earthquake periods.

Authors

Institutions

Publication Details

Journal
Frontiers in Astronomy and Space Sciences
Published
2024-09-03
DOI
https://doi.org/10.3389/fspas.2024.1415323
Citations
5
Primary Topic
Earthquake Detection and Analysis
Type
article
Field-Weighted Citation Impact
2.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prediction of ionospheric TEC during the occurrence of earthquakes in Indonesia using ARMA and CoK models

S. Mythili, S. Kiruthiga
5 citations
Frontiers in Astronomy and Space Sciences
Earthquake Detection and Analysis
2.67
article

Prediction of ionospheric TEC during the occurrence of earthquakes in Indonesia using ARMA and CoK models

S. Mythili, S. Kiruthiga
article en
5 citations

Abstract

Predicting ionospheric Total Electron Content (TEC) variations associated with seismic activity is crucial for mitigating potential disruptions in communication networks, particularly during earthquakes. This research investigates applying two modelling techniques, Autoregressive Moving Average (ARMA) and Cokriging (CoK) based models to forecast ionospheric TEC changes linked to seismic events in Indonesia. The study focuses on two significant earthquakes: the December 2004 Sumatra earthquake and the August 2012 Sulawesi earthquake. GPS TEC data from a BAKO station near Indonesia and solar and geomagnetic data were utilized to assess the causes of TEC variations. The December 2004 Sumatra earthquake, registering a magnitude of 9.1–9.3, exhibited notable TEC variations 5 days before the event. Analysis revealed that the TEC variations were weakly linked to solar and geomagnetic activities. Both ARMA and CoK models were employed to predict TEC variations during the Earthquakes. The ARMA model demonstrated a maximum TEC prediction of 50.92 TECU and a Root Mean Square Error (RMSE) value of 6.15, while the CoK model predicted a maximum TEC of 50.68 TECU with an RMSE value of 6.14. The August 2012 Sulawesi earthquake having a magnitude of 6.6, revealed TEC anomalies 6 days before the event. For both the Sumatra and Sulawesi earthquakes, the GPS TEC variations showed weak associations with solar and geomagnetic activities but stronger correlations with the earthquake-induced electric field for the considered two stations. The ARMA model predicted a maximum TEC of 54.43 TECU with an RMSE of 3.05, while the CoK model predicted a maximum TEC of 52.90 TECU with an RMSE of 7.35. Evaluation metrics including RMSE, Mean Absolute Deviation (MAD), Relative Error, and Normalized RMSE (NRMSE) were employed to assess the accuracy and reliability of the prediction models. The results indicated that while both models captured the general trend in TEC variations, nuances emerged in their responses to seismic events. The ARMA model demonstrated heightened sensitivity to seismic disturbances, particularly evident on the day of the earthquake, whereas the CoK model exhibited more consistent performance across pre- and post-earthquake periods.

Frontiers in Astronomy and Space SciencesVol. 11
Social Service Sericulture Project Trust (IN)
Openalex Percentile: Top 11%
Earthquake Detection and Analysis
2.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.