Series arc‐fault diagnosis using convolutional neural network via generalized S‐transform and power spectral density

Abstract It is difficult to identify an arc fault accurately when the loads on the user side are more complicated, which hinders the development of low‐voltage monitoring and pre‐warning inspection. This study acquired a series of arc‐fault signals according to IEC 62606. The main time‐frequency features were strengthened with high efficiency by applying the generalized S‐transform to them with a bi‐Gaussian window. Further, the power spectrum density determination allowed for the detection of imperceptible high‐frequency harmonic energy reflections, thus increasing the rate of arc‐fault diagnosis and making it suitable for arc‐fault monitoring of non‐linear loads. The final samples were trained and classified using a 2D convolutional neural network and the overall accuracy of identification was observed to be 98.13%, which involved various domestic loads, thus providing a reference for follow‐up arc‐fault monitoring and inspection research.

Authors

Institutions

Publication Details

Journal
IET Generation Transmission & Distribution
Published
2024-09-02
DOI
https://doi.org/10.1049/gtd2.13193
Citations
2
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Series arc‐fault diagnosis using convolutional neural network via generalized S‐transform and power spectral density

Penghe Zhang, Yiwei Qin
2 citations
IET Generation Transmission & Distribution
Electrical Fault Detection and Protection
0.42
article

Series arc‐fault diagnosis using convolutional neural network via generalized S‐transform and power spectral density

Penghe Zhang, Yiwei Qin
article en
2 citations

Abstract

Abstract It is difficult to identify an arc fault accurately when the loads on the user side are more complicated, which hinders the development of low‐voltage monitoring and pre‐warning inspection. This study acquired a series of arc‐fault signals according to IEC 62606. The main time‐frequency features were strengthened with high efficiency by applying the generalized S‐transform to them with a bi‐Gaussian window. Further, the power spectrum density determination allowed for the detection of imperceptible high‐frequency harmonic energy reflections, thus increasing the rate of arc‐fault diagnosis and making it suitable for arc‐fault monitoring of non‐linear loads. The final samples were trained and classified using a 2D convolutional neural network and the overall accuracy of identification was observed to be 98.13%, which involved various domestic loads, thus providing a reference for follow‐up arc‐fault monitoring and inspection research.

IET Generation Transmission & DistributionVol. 18(19)
State Grid Corporation of China (China) (CN), China Electric Power Research Institute
State Grid Corporation of China
Affordable and clean energy
Openalex Percentile: Top 38%
Electrical Fault Detection and Protection
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.