Rancang Bangun Green Portable Cooler Box

Freon is one of the refrigerants used in refrigeration systems. The refrigeration system has a very important role, namely to preserve food ingredients so that food can last longer. The use of freon is not only used in ships but is widely found in home appliances in refrigeration systems used in freezers, air conditioners, refrigerators, and dispensers. If more freon is used, the negative impact that arises is greater, namely the depletion of the ozone layer and global warming which can have a bad influence on health, the life of living things and the environment. The purpose of this researcher is to create a tool to reduce the negative impact of freon use, namely by using peltier as a cooling medium with environmentally friendly thermoelectric modules. This study uses trial and error methods. Where the trial process is carried out by turning on one of the working push buttons and observing the temperature value. Then it is processed by the control system, namely Arduino Mega which will later provide a PWM output signal to the IRF540 mosfet when the output temperature value is in line with the reference value and vice versa. The test of this tool was carried out by comparing measurements between the author's prototype tool and the standard measuring tool, namely the digital thermometer. Based on the test results, this device can produce a minimum temperature of 140C at 30-minute intervals without any media. The trial using 330ml bottled water can reach a temperature of 170C within 30 minutes in the cooler box. This tool is also equipped with an automatic monitoring system using a PWM signal in the form of a change in fan speed, which is 255 RPS maximum speed and when getting a PWM signal it changes to 50 RPS. The percentage of errors resulting from the comparison of standard measuring instruments and sensor values had the highest and lowest percentages of 2.37% and 0.84% in cold dispersion conditions without charge. Then the highest and lowest error percentages were 1.69% and 0.72% in the state of containing a load of 1 330ml mineral bottle. This ptototype uses data recording using Micro-SD as a data logger.

Authors

Institutions

Publication Details

Journal
Jupiter Publikasi Ilmu Keteknikan Industri Teknik Elektro dan Informatika
Published
2024-08-16
DOI
https://doi.org/10.61132/jupiter.v2i5.519
Primary Topic
Engineering and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rancang Bangun Green Portable Cooler Box

Diana Alia, Nindia Puspa Ashari, Henna Nurdiansari, Renta Novaliana et al.
Jupiter Publikasi Ilmu Keteknikan Industri Teknik Elektro dan Informatika
Engineering and Technology Innovations
article

Rancang Bangun Green Portable Cooler Box

Diana Alia, Nindia Puspa Ashari, Henna Nurdiansari, Renta Novaliana, Eddi Eddi
article en

Abstract

Freon is one of the refrigerants used in refrigeration systems. The refrigeration system has a very important role, namely to preserve food ingredients so that food can last longer. The use of freon is not only used in ships but is widely found in home appliances in refrigeration systems used in freezers, air conditioners, refrigerators, and dispensers. If more freon is used, the negative impact that arises is greater, namely the depletion of the ozone layer and global warming which can have a bad influence on health, the life of living things and the environment. The purpose of this researcher is to create a tool to reduce the negative impact of freon use, namely by using peltier as a cooling medium with environmentally friendly thermoelectric modules. This study uses trial and error methods. Where the trial process is carried out by turning on one of the working push buttons and observing the temperature value. Then it is processed by the control system, namely Arduino Mega which will later provide a PWM output signal to the IRF540 mosfet when the output temperature value is in line with the reference value and vice versa. The test of this tool was carried out by comparing measurements between the author's prototype tool and the standard measuring tool, namely the digital thermometer. Based on the test results, this device can produce a minimum temperature of 140C at 30-minute intervals without any media. The trial using 330ml bottled water can reach a temperature of 170C within 30 minutes in the cooler box. This tool is also equipped with an automatic monitoring system using a PWM signal in the form of a change in fan speed, which is 255 RPS maximum speed and when getting a PWM signal it changes to 50 RPS. The percentage of errors resulting from the comparison of standard measuring instruments and sensor values had the highest and lowest percentages of 2.37% and 0.84% in cold dispersion conditions without charge. Then the highest and lowest error percentages were 1.69% and 0.72% in the state of containing a load of 1 330ml mineral bottle. This ptototype uses data recording using Micro-SD as a data logger.

Jupiter Publikasi Ilmu Keteknikan Industri Teknik Elektro dan InformatikaVol. 2(5)
Institut Sains dan Teknologi Terpadu Surabaya (ID)
Responsible consumption and production
Openalex Percentile: Top 88%
Engineering and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.