Electrokinetic particle trapping in microfluidic wells using conductive nanofiber mats

The frequency dependence of electrokinetic particle trapping using large-area (>mm<sup>2</sup>) conductive carbon nanofiber (CNF) mat electrodes is investigated. The fibers provide nanoscale geometric features for the generation of high electric field gradients, which is necessary for particle trapping via dielectrophoresis (DEP). A device was fabricated with an array of microfluidic wells for repeated experiments; each well included a CNF mat electrode opposing an aluminum electrode. Fluorescent microspheres (1 µm) were trapped at various electric field frequencies between 30 kHz and 1 MHz. Digital images of each well were analyzed to quantify particle trapping. DEP trapping by the CNF mats was greater at all tested frequencies than that of the control of no applied field, and the greatest trapping was observed at a frequency of 600 kHz, where electrothermal flow is more significantly weakened than DEP. Theoretical analysis and measured impedance spectra indicate that this result was due to a combination of the frequency dependence of DEP and capacitive behavior of the well-based device.

Authors

Institutions

Publication Details

Journal
Electrophoresis
Published
2024-09-02
DOI
https://doi.org/10.1002/elps.202400051
Citations
8
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
1.48

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrokinetic particle trapping in microfluidic wells using conductive nanofiber mats

Stuart J. Williams, Tonoy K. Mondal, J. Hunter West
8 citations
Electrophoresis
Microfluidic and Bio-sensing Technologies
1.48
article

Electrokinetic particle trapping in microfluidic wells using conductive nanofiber mats

Stuart J. Williams, Tonoy K. Mondal, J. Hunter West
article en
8 citations

Abstract

The frequency dependence of electrokinetic particle trapping using large-area (>mm<sup>2</sup>) conductive carbon nanofiber (CNF) mat electrodes is investigated. The fibers provide nanoscale geometric features for the generation of high electric field gradients, which is necessary for particle trapping via dielectrophoresis (DEP). A device was fabricated with an array of microfluidic wells for repeated experiments; each well included a CNF mat electrode opposing an aluminum electrode. Fluorescent microspheres (1 µm) were trapped at various electric field frequencies between 30 kHz and 1 MHz. Digital images of each well were analyzed to quantify particle trapping. DEP trapping by the CNF mats was greater at all tested frequencies than that of the control of no applied field, and the greatest trapping was observed at a frequency of 600 kHz, where electrothermal flow is more significantly weakened than DEP. Theoretical analysis and measured impedance spectra indicate that this result was due to a combination of the frequency dependence of DEP and capacitive behavior of the well-based device.

ElectrophoresisVol. 46(15)
University of Louisville (US)
National Science Foundation
Openalex Percentile: Top 19%
Microfluidic and Bio-sensing Technologies
1.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.