Study of effective location of shear wall in multi-storeyed buildings for optimum seismic response

In the seismic resistant design of high-rise structures, shear walls which are constructed along the height of the building are capable of transferring lateral forces from peripheral walls, floors, and roofs to the ground foundation. The main objective of the present study is to determine the effective location for shear walls in a multi-storey building for an optimum seismic response. The “Dynamic Response Spectrum method” of analysis of the building is done using ETABS. The effectiveness of shear walls has been studied by considering four different models. Model-I is a bare frame structural system without a shear wall and the other three models are dual-type structural systems with shear walls at different locations. In this study, a 16x16m plan with G+15 stories RC building with a total height of about 48m is analysed in zone V by providing shear walls of 250mm thick at different locations in the building. From the analysis results it is observed that the model with a shear wall placed at the centre of the building is more effective in resisting seismic forces when compared to other models.

Publication Details

Journal
ARPN Journal of Engineering and Applied Sciences
Published
2024-09-03
DOI
https://doi.org/10.59018/062496
Primary Topic
Seismic and Structural Analysis of Tall Buildings
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of effective location of shear wall in multi-storeyed buildings for optimum seismic response

ARPN Journal of Engineering and Applied Sciences
Seismic and Structural Analysis of Tall Buildings
article

Study of effective location of shear wall in multi-storeyed buildings for optimum seismic response

article en

Abstract

In the seismic resistant design of high-rise structures, shear walls which are constructed along the height of the building are capable of transferring lateral forces from peripheral walls, floors, and roofs to the ground foundation. The main objective of the present study is to determine the effective location for shear walls in a multi-storey building for an optimum seismic response. The “Dynamic Response Spectrum method” of analysis of the building is done using ETABS. The effectiveness of shear walls has been studied by considering four different models. Model-I is a bare frame structural system without a shear wall and the other three models are dual-type structural systems with shear walls at different locations. In this study, a 16x16m plan with G+15 stories RC building with a total height of about 48m is analysed in zone V by providing shear walls of 250mm thick at different locations in the building. From the analysis results it is observed that the model with a shear wall placed at the centre of the building is more effective in resisting seismic forces when compared to other models.

ARPN Journal of Engineering and Applied Sciences
Sustainable cities and communities
Openalex Percentile: Top 83%
Seismic and Structural Analysis of Tall Buildings
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.