Optimising 4D imaging of fast-oscillating structures using X-ray microtomography with retrospective gating

Imaging the internal architecture of fast-vibrating structures at micrometer scale and kilohertz frequencies poses great challenges for numerous applications, including the study of biological oscillators, mechanical testing of materials, and process engineering. Over the past decade, X-ray microtomography with retrospective gating has shown very promising advances in meeting these challenges. However, breakthroughs are still expected in acquisition and reconstruction procedures to keep improving the spatiotemporal resolution, and study the mechanics of fast-vibrating multiscale structures. Thereby, this works aims to improve this imaging technique by minimising streaking and motion blur artefacts through the optimisation of experimental parameters. For that purpose, we have coupled a numerical approach relying on tomography simulation with vibrating particles with known and ideal 3D geometry (micro-spheres or fibres) with experimental campaigns. These were carried out on soft composites, imaged in synchrotron X-ray beamlines while oscillating up to 400 Hz, thanks to a custom-developed vibromechanical device. This approach yields homogeneous angular sampling of projections and gives reliable predictions of image quality degradation due to motion blur. By overcoming several technical and scientific barriers limiting the feasibility and reproducibility of such investigations, we provide guidelines to enhance gated-CT 4D imaging for the analysis of heterogeneous, high-frequency oscillating materials.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-09-03
DOI
https://doi.org/10.1038/s41598-024-68684-1
Citations
3
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
1.82

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimising 4D imaging of fast-oscillating structures using X-ray microtomography with retrospective gating

Andrew King, Lucie Bailly, Antoine Klos, Laurent Orgéas et al.
3 citations
Scientific Reports
Advanced X-ray Imaging Techniques
1.82
article

Optimising 4D imaging of fast-oscillating structures using X-ray microtomography with retrospective gating

Andrew King, Lucie Bailly, Antoine Klos, Laurent Orgéas, Sabine Rolland du Roscoat, Ludovic Broche, Nathalie Henrich Bernardoni
article en
3 citations

Abstract

Imaging the internal architecture of fast-vibrating structures at micrometer scale and kilohertz frequencies poses great challenges for numerous applications, including the study of biological oscillators, mechanical testing of materials, and process engineering. Over the past decade, X-ray microtomography with retrospective gating has shown very promising advances in meeting these challenges. However, breakthroughs are still expected in acquisition and reconstruction procedures to keep improving the spatiotemporal resolution, and study the mechanics of fast-vibrating multiscale structures. Thereby, this works aims to improve this imaging technique by minimising streaking and motion blur artefacts through the optimisation of experimental parameters. For that purpose, we have coupled a numerical approach relying on tomography simulation with vibrating particles with known and ideal 3D geometry (micro-spheres or fibres) with experimental campaigns. These were carried out on soft composites, imaged in synchrotron X-ray beamlines while oscillating up to 400 Hz, thanks to a custom-developed vibromechanical device. This approach yields homogeneous angular sampling of projections and gives reliable predictions of image quality degradation due to motion blur. By overcoming several technical and scientific barriers limiting the feasibility and reproducibility of such investigations, we provide guidelines to enhance gated-CT 4D imaging for the analysis of heterogeneous, high-frequency oscillating materials.

Scientific ReportsVol. 14(1)
Institut polytechnique de Grenoble (FR), Centre National de la Recherche Scientifique (FR), Synchrotron soleil (FR), European Synchrotron Radiation Facility (FR), GIPSA-Lab (FR), Université Grenoble Alpes (FR)
Université Grenoble Alpes, Agence Nationale de la Recherche, European Synchrotron Radiation Facility, Centre National de la Recherche Scientifique, Institut Carnot PolyNat
Openalex Percentile: Top 16%
Advanced X-ray Imaging Techniques
1.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.