Optimal utilization of frequency ancillary services in modern power systems

The widespread global adoption of wind energy sources has established a significant presence in the existing power grid. However, the massive integration of intermittent wind energy poses forecasting errors, prompting the need for supplementary reserves from conventional energy sources with increased operational expenses and carbon emissions. Hence, to facilitate the seamless operation of large-scale wind-integrated power grids, it is imperative to harness the potential of renewable energy sources and leverage flexible loads to deliver power-balancing services. In this research, dynamic real-time power dispatch strategies have been developed for the Automatic Generation Control (AGC) system to integrate the reserve capacities of conventional generation units and wind power plants and utilize the demand response capabilities of flexible loads for power balancing services. A comprehensive power system grid model was developed in DigSilent PowerFactory software, consisting of coal-based energy systems, wind energy systems, gas turbines, and cold storage units as flexible loads. The study is divided into different case studies to assess the impact of each scenario on system operation in mitigating the forecasting errors of wind power plants. Further, a comparative analysis was performed to illustrate the effectiveness of each case study. The analysis showed that Case Study III, where reserves are provided by coal energy systems and cold storage units, yielded the highest reduction in Positive Regulation (PR) and Negative Regulation (NR) errors, at 89.0% and 94.15%, respectively. Conversely, Case Study IV demonstrated the least reduction in errors, with 67.82% in PR and 78.41% in NR. However, it indicates that reserves can be supplied from wind energy systems and flexible loads without the support of conventional power plants.

Authors

Institutions

Publication Details

Journal
e-Prime - Advances in Electrical Engineering Electronics and Energy
Published
2024-09-01
DOI
https://doi.org/10.1016/j.prime.2024.100755
Citations
8
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
1.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal utilization of frequency ancillary services in modern power systems

Zahid Ullah, Giambattista Gruosso, Kaleem Ullah, Abdul Basit
8 citations
e-Prime - Advances in Electrical Engineering Electronics and Energy
Frequency Control in Power Systems
1.67
article

Optimal utilization of frequency ancillary services in modern power systems

Zahid Ullah, Giambattista Gruosso, Kaleem Ullah, Abdul Basit
article en
8 citations

Abstract

The widespread global adoption of wind energy sources has established a significant presence in the existing power grid. However, the massive integration of intermittent wind energy poses forecasting errors, prompting the need for supplementary reserves from conventional energy sources with increased operational expenses and carbon emissions. Hence, to facilitate the seamless operation of large-scale wind-integrated power grids, it is imperative to harness the potential of renewable energy sources and leverage flexible loads to deliver power-balancing services. In this research, dynamic real-time power dispatch strategies have been developed for the Automatic Generation Control (AGC) system to integrate the reserve capacities of conventional generation units and wind power plants and utilize the demand response capabilities of flexible loads for power balancing services. A comprehensive power system grid model was developed in DigSilent PowerFactory software, consisting of coal-based energy systems, wind energy systems, gas turbines, and cold storage units as flexible loads. The study is divided into different case studies to assess the impact of each scenario on system operation in mitigating the forecasting errors of wind power plants. Further, a comparative analysis was performed to illustrate the effectiveness of each case study. The analysis showed that Case Study III, where reserves are provided by coal energy systems and cold storage units, yielded the highest reduction in Positive Regulation (PR) and Negative Regulation (NR) errors, at 89.0% and 94.15%, respectively. Conversely, Case Study IV demonstrated the least reduction in errors, with 67.82% in PR and 78.41% in NR. However, it indicates that reserves can be supplied from wind energy systems and flexible loads without the support of conventional power plants.

e-Prime - Advances in Electrical Engineering Electronics and EnergyVol. 9
Pakistan Telecommunication Company (Pakistan) (PK), University of Engineering and Technology Peshawar (PK), Politecnico di Milano (IT)
United States Agency for International Development, Pakistan Science Foundation
Affordable and clean energy
Openalex Percentile: Top 16%
Frequency Control in Power Systems
1.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.