Development of a fuzzy logic-based model for assessing the reliability of relay protection systems

This article presents a reliability assessment model for relay protection devices using fuzzy logic. It introduces an algorithm for simulating these devices, employing the Mamdani model with an "if-then" rule base. Inputs include the percentage of correct operation and the frequency of correct and incorrect operations. Implemented in Matlab with 21 rules, the fuzzy logic model uses triangular membership functions for input and output variables, with defuzzification via the center of gravity method. The model was tested using statistical data from SIEMENS SIPROTEC terminals, specifically distance protection and differential protection devices for transformers and autotransformers. The assessment considers operation frequencies for 1 to 3 devices, combining statistical and simulation data for a comprehensive analysis. Results show that including operation frequencies improves evaluation accuracy. The proposed model not only assesses current reliability but also predicts future behavior, aiding in the planning and optimization of relay protection systems. This model is valuable for professionals in generating companies, grid organizations, and operational dispatch control entities, helping them analyze relay protection performance and develop strategies to ensure reliable operation. The research focuses on the reliability of relay protection devices in power systems, addressing the need for a more accurate and comprehensive evaluation method. Traditional methods may not fully account for the complexities in modern microprocessor-based protections. This study aims to enhance reliability assessments through a model that integrates statistical data and simulation techniques, ultimately supporting better planning and optimization of relay protection systems

Authors

Institutions

Publication Details

Journal
Eastern-European Journal of Enterprise Technologies
Published
2024-08-30
DOI
https://doi.org/10.15587/1729-4061.2024.310549
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a fuzzy logic-based model for assessing the reliability of relay protection systems

Gulmira Yerbolkyzy, Galina Tatkeyeva, Aigul Uakhitova
Eastern-European Journal of Enterprise Technologies
Electric Power Systems and Control
article

Development of a fuzzy logic-based model for assessing the reliability of relay protection systems

Gulmira Yerbolkyzy, Galina Tatkeyeva, Aigul Uakhitova
article en

Abstract

This article presents a reliability assessment model for relay protection devices using fuzzy logic. It introduces an algorithm for simulating these devices, employing the Mamdani model with an "if-then" rule base. Inputs include the percentage of correct operation and the frequency of correct and incorrect operations. Implemented in Matlab with 21 rules, the fuzzy logic model uses triangular membership functions for input and output variables, with defuzzification via the center of gravity method. The model was tested using statistical data from SIEMENS SIPROTEC terminals, specifically distance protection and differential protection devices for transformers and autotransformers. The assessment considers operation frequencies for 1 to 3 devices, combining statistical and simulation data for a comprehensive analysis. Results show that including operation frequencies improves evaluation accuracy. The proposed model not only assesses current reliability but also predicts future behavior, aiding in the planning and optimization of relay protection systems. This model is valuable for professionals in generating companies, grid organizations, and operational dispatch control entities, helping them analyze relay protection performance and develop strategies to ensure reliable operation. The research focuses on the reliability of relay protection devices in power systems, addressing the need for a more accurate and comprehensive evaluation method. Traditional methods may not fully account for the complexities in modern microprocessor-based protections. This study aims to enhance reliability assessments through a model that integrates statistical data and simulation techniques, ultimately supporting better planning and optimization of relay protection systems

Eastern-European Journal of Enterprise TechnologiesVol. 4(2 (130))
S.Seifullin Kazakh Agro Technical University (KZ)
Openalex Percentile: Top 88%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.