Automated Breast Ultrasound for Evaluating Response to Neoadjuvant Therapy: A Comparison with Magnetic Resonance Imaging

<b>Background:</b> Neoadjuvant chemotherapy (NAC) is currently used for treating breast cancer in selected cases. Our study aims to evaluate the role of automated breast ultrasound (ABUS) in the assessment of response to NAC and compare the ABUS results with MRI. <b>Methods:</b> A total of 52 consecutive patients were included in this study. ABUS and MRI sensitivity (SE), specificity (SP), diagnostic accuracy (DA), positive predictive value (PPV), and negative predictive value (NPV) were calculated and represented using Area Under ROC Curve (ROC) analysis, searching for any significant difference (<i>p</i> < 0.05). The McNemar test was used searching for any significant difference in terms of sensitivity by comparing the ABUS and MRI results. The inter-observer agreement between the readers in evaluating the response to NAC for both MRI and ABUS was calculated using Cohen's kappa k coefficient. <b>Results:</b> A total of 35 cases of complete response and 17 cases of persistent disease were found. MRI showed SE, SP, DA, PPV, and NPV values of 100%, 88%, 92%, 81%, and 100%, respectively, with an AUC value of 0.943 (<i>p</i> < 0.0001). ABUS showed SE, SP, DA, PPV, and NPV values of 88%, 94%, 92%, 89%, and 94%, respectively, with an AUC of 0.913 (<i>p</i> < 0.0001). The McNemar test revealed no significant difference (<i>p</i> = 0.1250). The inter-observer agreement between the two readers in evaluating the response to NAC for MRI and ABUS was, respectively, 0.88 and 0.89. <b>Conclusions:</b> Automatic breast ultrasound represents a new accurate, tri-dimensional and operator-independent tool for evaluating patients referred to NAC.

Authors

Institutions

Publication Details

Journal
Journal of Personalized Medicine
Published
2024-08-31
DOI
https://doi.org/10.3390/jpm14090930
Citations
2
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated Breast Ultrasound for Evaluating Response to Neoadjuvant Therapy: A Comparison with Magnetic Resonance Imaging

Michele Telegrafo, Marco Moschetta, Angela Gurrado, Michele Maruccia et al.
2 citations
Journal of Personalized Medicine
MRI in cancer diagnosis
0.81
article

Automated Breast Ultrasound for Evaluating Response to Neoadjuvant Therapy: A Comparison with Magnetic Resonance Imaging

Michele Telegrafo, Marco Moschetta, Angela Gurrado, Michele Maruccia, Claudia Rita Catacchio, Federico Cofone, Amato Antonio Stabile Ianora, Stefania Luigia Stucci
article en
2 citations

Abstract

<b>Background:</b> Neoadjuvant chemotherapy (NAC) is currently used for treating breast cancer in selected cases. Our study aims to evaluate the role of automated breast ultrasound (ABUS) in the assessment of response to NAC and compare the ABUS results with MRI. <b>Methods:</b> A total of 52 consecutive patients were included in this study. ABUS and MRI sensitivity (SE), specificity (SP), diagnostic accuracy (DA), positive predictive value (PPV), and negative predictive value (NPV) were calculated and represented using Area Under ROC Curve (ROC) analysis, searching for any significant difference (<i>p</i> < 0.05). The McNemar test was used searching for any significant difference in terms of sensitivity by comparing the ABUS and MRI results. The inter-observer agreement between the readers in evaluating the response to NAC for both MRI and ABUS was calculated using Cohen's kappa k coefficient. <b>Results:</b> A total of 35 cases of complete response and 17 cases of persistent disease were found. MRI showed SE, SP, DA, PPV, and NPV values of 100%, 88%, 92%, 81%, and 100%, respectively, with an AUC value of 0.943 (<i>p</i> < 0.0001). ABUS showed SE, SP, DA, PPV, and NPV values of 88%, 94%, 92%, 89%, and 94%, respectively, with an AUC of 0.913 (<i>p</i> < 0.0001). The McNemar test revealed no significant difference (<i>p</i> = 0.1250). The inter-observer agreement between the two readers in evaluating the response to NAC for MRI and ABUS was, respectively, 0.88 and 0.89. <b>Conclusions:</b> Automatic breast ultrasound represents a new accurate, tri-dimensional and operator-independent tool for evaluating patients referred to NAC.

Journal of Personalized MedicineVol. 14(9)
University of Bari Aldo Moro (IT)
Good health and well-being
Openalex Percentile: Top 26%
MRI in cancer diagnosis
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.