Fracture strain improving via structural austenitic stainless steel-coated 22MnB5 plates

A total of 316 austenitic stainless steel (ASS) coatings were deposited on 22MnB5 press-hardening steel plates by varying the substrate bias voltages using a magnetron sputtering technique and quenched in a flat mold with cooling water. The substrate bias current and ion-bombardment energy densities increased up to 0.5 mA/mm2 and 50 J/mm2 at a high voltage of −100 V, and, therefore, the variations in the coatings’ morphologies were owing to the increases in the ion bombardment. The porous bulk pattern appeared in the quenched ASS coating at −100 V, clearly different from the porous columnar structure of the others at −50 and −75 V. The γ-Fe and α-Fe phases were observed from the diffraction peaks, presented the ASS coating and 22MnB5 substrate, respectively. There was no intermetallic compound (IMC) peak detected. In addition, the diffusion layer of the quenched ASS-coated plate was observed, in which its morphology was different from the quenched martensite (M) plate, and proved to be the α-Fe microstructure by the very low α-Fe peak at the standard (110) position. The bright image of TEM and the select area electron diffraction pattern indicated the nanostructure of the quenched ASS coating. The nanohardness of the ASS coating, diffusion layer, and M plate (7.36, 3.60, and 6.25 GPa, respectively) was detected, indirectly proving an α-Fe structure of the diffusion layer. The fracture angles of the 316-coated plates significantly improved from 51.82° at −50 V, 53.77° at −75 V to 57.38° at −100 V, as the ASS structure changed to be porous bulk pattern. The clearance of IMC, coating’s porous bulk pattern, and the low hardness α-Fe diffusion layer benefited for the fracture strain by lengthening the pathway of the crack’s development and blocking the further crack’s propagation, respectively.

Authors

Institutions

Publication Details

Journal
Journal of Vacuum Science & Technology A Vacuum Surfaces and Films
Published
2024-09-01
DOI
https://doi.org/10.1116/6.0003742
Citations
1
Primary Topic
Metal and Thin Film Mechanics
Type
article
Field-Weighted Citation Impact
0.27

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fracture strain improving via structural austenitic stainless steel-coated 22MnB5 plates

Zhuo Zhao, Yanwen Zhou, Pengchao Yu, Maoqing Tian et al.
1 citations
Journal of Vacuum Science & Technology A Vacuum Surfaces and Films
Metal and Thin Film Mechanics
0.27
article

Fracture strain improving via structural austenitic stainless steel-coated 22MnB5 plates

Zhuo Zhao, Yanwen Zhou, Pengchao Yu, Maoqing Tian, Jiashun Lv
article en
1 citations

Abstract

A total of 316 austenitic stainless steel (ASS) coatings were deposited on 22MnB5 press-hardening steel plates by varying the substrate bias voltages using a magnetron sputtering technique and quenched in a flat mold with cooling water. The substrate bias current and ion-bombardment energy densities increased up to 0.5 mA/mm2 and 50 J/mm2 at a high voltage of −100 V, and, therefore, the variations in the coatings’ morphologies were owing to the increases in the ion bombardment. The porous bulk pattern appeared in the quenched ASS coating at −100 V, clearly different from the porous columnar structure of the others at −50 and −75 V. The γ-Fe and α-Fe phases were observed from the diffraction peaks, presented the ASS coating and 22MnB5 substrate, respectively. There was no intermetallic compound (IMC) peak detected. In addition, the diffusion layer of the quenched ASS-coated plate was observed, in which its morphology was different from the quenched martensite (M) plate, and proved to be the α-Fe microstructure by the very low α-Fe peak at the standard (110) position. The bright image of TEM and the select area electron diffraction pattern indicated the nanostructure of the quenched ASS coating. The nanohardness of the ASS coating, diffusion layer, and M plate (7.36, 3.60, and 6.25 GPa, respectively) was detected, indirectly proving an α-Fe structure of the diffusion layer. The fracture angles of the 316-coated plates significantly improved from 51.82° at −50 V, 53.77° at −75 V to 57.38° at −100 V, as the ASS structure changed to be porous bulk pattern. The clearance of IMC, coating’s porous bulk pattern, and the low hardness α-Fe diffusion layer benefited for the fracture strain by lengthening the pathway of the crack’s development and blocking the further crack’s propagation, respectively.

Journal of Vacuum Science & Technology A Vacuum Surfaces and FilmsVol. 42(5)
University of Science and Technology Liaoning (CN), Ansteel (China) (CN)
National Natural Science Foundation of China-Liaoning Joint Fund
Openalex Percentile: Top 51%
Metal and Thin Film Mechanics
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.