Study of a Novel 3D Façade Configuration and Its Impact on Energy Performance and Office Space Sustainability

This research paper examines how multi-angled façade systems improve and optimise energy performance compared to a flat façade and meet sustainability targets for lower energy use to align with UN SDGs 3, 11, 12, and 13. The multi-angled façade system does not tilt up and down. Instead, it employs two different window orientations on a vertical axis (left and right). The large portion orients more to the north to allow more daylight to penetrate inside the room, and the small part is oriented more to the south to provide passive solar heating. The investigations in this research paper were carried out using version 4.8 of the IDA ICE software, and the researchers evaluated the energy consumption, the energy action through the façade, and the building’s inside operative temperature. The results of this paper present the simulation findings for primary energy consumption in different scenarios. For example, the researchers explain that one can save 6.3 kWh/(m2·year) when using a multi-angled façade system compared to a flat façade. This is in addition to improving the thermal indoor climate that results from using the façades. The conclusions of the research show that the façade with multiple angles maximises using daylight and optimises solar power, thus avoiding overheating issues.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-09-03
DOI
https://doi.org/10.3390/en17174420
Citations
3
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of a Novel 3D Façade Configuration and Its Impact on Energy Performance and Office Space Sustainability

Noha Saleeb, Loay Akram Hannoudi, George Dafoulas
3 citations
Energies
Building Energy and Comfort Optimization
0.80
article

Study of a Novel 3D Façade Configuration and Its Impact on Energy Performance and Office Space Sustainability

Noha Saleeb, Loay Akram Hannoudi, George Dafoulas
article en
3 citations

Abstract

This research paper examines how multi-angled façade systems improve and optimise energy performance compared to a flat façade and meet sustainability targets for lower energy use to align with UN SDGs 3, 11, 12, and 13. The multi-angled façade system does not tilt up and down. Instead, it employs two different window orientations on a vertical axis (left and right). The large portion orients more to the north to allow more daylight to penetrate inside the room, and the small part is oriented more to the south to provide passive solar heating. The investigations in this research paper were carried out using version 4.8 of the IDA ICE software, and the researchers evaluated the energy consumption, the energy action through the façade, and the building’s inside operative temperature. The results of this paper present the simulation findings for primary energy consumption in different scenarios. For example, the researchers explain that one can save 6.3 kWh/(m2·year) when using a multi-angled façade system compared to a flat façade. This is in addition to improving the thermal indoor climate that results from using the façades. The conclusions of the research show that the façade with multiple angles maximises using daylight and optimises solar power, thus avoiding overheating issues.

EnergiesVol. 17(17)
Middlesex University London (GB)
Affordable and clean energy
Openalex Percentile: Top 29%
Building Energy and Comfort Optimization
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study of a Novel 3D Façade Configuration and Its Impact on Energy Performance and Office Space Sustainability — Noha Saleeb, Loay Akram Hannoudi, et al. · Energies (2024) | TGRS Research Map | TGRS