Evaluation and Comparison of the Dose Received by the Mandible, Maxilla, and Teeth in Two Methods of Three-dimensional Conformal Radiation Therapy and Helical Tomotherapy

The findings of the comparison of the two treatment approaches revealed that the HT method was more than 50% more effective than the 3D-CRT method in sustaining organs at risk (OARs) and the target volume dose. In general, dosimetric coverage, homogeneity, conformity indices, and the absence of cold and hot patches showed that HT produced targets with greater accuracy than 3D-CRT. In addition, HT outperformed 3D-CRT in protecting important structures (OARs). HT as a result has the potential to be a more effective method of treatment for those with H and NC and involvement of regional lymph nodes.

Authors

Institutions

Publication Details

Journal
Journal of Medical Signals & Sensors
Published
2024-09-01
DOI
https://doi.org/10.4103/jmss.jmss_42_23
Citations
1
Primary Topic
Head and Neck Cancer Studies
Type
article
Field-Weighted Citation Impact
0.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation and Comparison of the Dose Received by the Mandible, Maxilla, and Teeth in Two Methods of Three-dimensional Conformal Radiation Therapy and Helical Tomotherapy

Mohsen Saeb, Pegah Moradi Khaniabadi, Bita Moradi Khaniabadi, Nadia Najafizade et al.
1 citations
Journal of Medical Signals & Sensors
Head and Neck Cancer Studies
0.58
article

Evaluation and Comparison of the Dose Received by the Mandible, Maxilla, and Teeth in Two Methods of Three-dimensional Conformal Radiation Therapy and Helical Tomotherapy

Mohsen Saeb, Pegah Moradi Khaniabadi, Bita Moradi Khaniabadi, Nadia Najafizade, Daryoush Shahbazi‐Gahrouei, Zahra Pourparvar
article en
1 citations

Abstract

The findings of the comparison of the two treatment approaches revealed that the HT method was more than 50% more effective than the 3D-CRT method in sustaining organs at risk (OARs) and the target volume dose. In general, dosimetric coverage, homogeneity, conformity indices, and the absence of cold and hot patches showed that HT produced targets with greater accuracy than 3D-CRT. In addition, HT outperformed 3D-CRT in protecting important structures (OARs). HT as a result has the potential to be a more effective method of treatment for those with H and NC and involvement of regional lymph nodes.

Journal of Medical Signals & SensorsVol. 14(9)
Isfahan University of Medical Sciences (IR), Sultan Qaboos University (OM)
Isfahan University of Medical Sciences
Good health and well-being
Openalex Percentile: Top 31%
Head and Neck Cancer Studies
0.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation and Comparison of the Dose Received by the Mandible, Maxilla, and Teeth in Two Methods of Three-dimensional Conformal Radiation Therapy and Helical Tomotherapy — Mohsen Saeb, Pegah Moradi Khaniabadi, et al. · Journal of Medical Signals & Sensors (2024) | TGRS Research Map | TGRS