The MITRIS RESILIA Valve: New Skin for a Proven Design

By incorporating the best features of the Carpentier-Edwards PERIMOUNT Magna Mitral Ease valve (Edwards Lifesciences Corporation, Irvine, California) and INSPIRIS RESILIA tissue (Edwards Lifesciences Corporation, Irvine, California), the mitris valve inherits the advantages of the remarkable hemodynamic performance of the former and the durability of the latter. In this paper, we will summarize the process that led to the creation of this new valve and report on the first implant's feasibility and first impression. The mitris valve has an overall implantability profile, overlapping the previous generation with no added challenges, but compared to the PERIMOUNT Magna Mitral Ease valve, the mitris valve boasts a more pliable saddle-shaped sewing cuff that is specifically tailored to fit the complex structure of the mitral valve with a lower stent height. This could be particularly beneficial in the context of double-valve replacement, as it may prevent any disturbance to the bioprosthesis located in the aortic position in small annulus. This could also prevent some rare but unpleasant complications such as left ventricle outflow obstruction or rupture of the atrioventricular sulcus. In addition, it could allow for better adherence to the saddle-shaped annulus of the mitral valve with the possibility of less stress (and therefore fibrosis) on the valve tissue, while further reducing the degeneration time. Furthermore, thanks to the possibility of being temporarily adjusted inwards, it is possible to ensure greater implantability compared to the previous generation of Magna Edwards mitral valves. Thanks to INSPIRIS technology, which prevents the generation of free aldehydes that promote oxidation and calcification of pericardial tissue, it is possible to assume that the durability will probably also improve. This reinforces the trustworthiness of the mitris valve.

Authors

Institutions

Publication Details

Journal
Surgical Technology Online
Published
2024-09-03
DOI
https://doi.org/10.52198/24.sti.44.cv1792
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The MITRIS RESILIA Valve: New Skin for a Proven Design

Giulia Ciccarelli, Ruggero De Paulis, Giulio Folino, Andrea Salica et al.
Surgical Technology Online
Cardiac Valve Diseases and Treatments
article

The MITRIS RESILIA Valve: New Skin for a Proven Design

Giulia Ciccarelli, Ruggero De Paulis, Giulio Folino, Andrea Salica, Luca Weltert, Gino Gerosa, Lorenzo Guerrieri Wolf, Samuel Fusca, Salvatore D’Aleo, Raffaele Scaffa, Alessandro Bellisario, Alessandro Ricci
article en

Abstract

By incorporating the best features of the Carpentier-Edwards PERIMOUNT Magna Mitral Ease valve (Edwards Lifesciences Corporation, Irvine, California) and INSPIRIS RESILIA tissue (Edwards Lifesciences Corporation, Irvine, California), the mitris valve inherits the advantages of the remarkable hemodynamic performance of the former and the durability of the latter. In this paper, we will summarize the process that led to the creation of this new valve and report on the first implant's feasibility and first impression. The mitris valve has an overall implantability profile, overlapping the previous generation with no added challenges, but compared to the PERIMOUNT Magna Mitral Ease valve, the mitris valve boasts a more pliable saddle-shaped sewing cuff that is specifically tailored to fit the complex structure of the mitral valve with a lower stent height. This could be particularly beneficial in the context of double-valve replacement, as it may prevent any disturbance to the bioprosthesis located in the aortic position in small annulus. This could also prevent some rare but unpleasant complications such as left ventricle outflow obstruction or rupture of the atrioventricular sulcus. In addition, it could allow for better adherence to the saddle-shaped annulus of the mitral valve with the possibility of less stress (and therefore fibrosis) on the valve tissue, while further reducing the degeneration time. Furthermore, thanks to the possibility of being temporarily adjusted inwards, it is possible to ensure greater implantability compared to the previous generation of Magna Edwards mitral valves. Thanks to INSPIRIS technology, which prevents the generation of free aldehydes that promote oxidation and calcification of pericardial tissue, it is possible to assume that the durability will probably also improve. This reinforces the trustworthiness of the mitris valve.

Surgical Technology OnlineVol. 44
European Hospital (IT)
Responsible consumption and production
Openalex Percentile: Top 74%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.