Repeatability of alkaline inorganic phosphate quantification in the skeletal muscle using <sup>31</sup>P‐magnetic resonance spectroscopy at 3 T

The detection of a secondary inorganic phosphate (Pi) resonance, a possible marker of mitochondrial content in vivo, using phosphorus magnetic resonance spectroscopy (<sup>31</sup>P-MRS), poses technical challenges at 3 Tesla (T). Overcoming these challenges is imperative for the integration of this biomarker into clinical research. To evaluate the repeatability and reliability of measuring resting skeletal muscle alkaline Pi (Pi<sub>alk</sub>) using with <sup>31</sup>P-MRS at 3 T. After an initial set of experiments on five subjects to optimize the sequence, resting <sup>31</sup>P-MRS of the quadriceps muscles were acquired on two visits (~4 days apart) using an intra-subjects design, from 13 sedentary to moderately active young male and female adults (22 ± 3 years old) within a whole-body 3 T MR system. Measurement variability attributed to changes in coil position, shimming procedure, and spectral analysis were quantified. <sup>31</sup>P-MRS data were acquired with a <sup>31</sup>P/-proton (<sup>1</sup>H) dual-tuned surface coil positioned on the quadriceps using a pulse-acquire sequence. Test-retest absolute and relative repeatability was analyzed using the coefficient of variation (CV) and intra-class correlation coefficients (ICC), respectively. After sequence parameter optimization, Pi<sub>alk</sub> demonstrated high intra-subject repeatability (CV: 10.6 ± 5.4%, ICC: 0.80). Proximo-distal change in coil position along the length of the quadriceps introduced Pi<sub>alk</sub> quantitation variability (CV: 28 ± 5%), due to magnetic field inhomogeneity with more distal coil locations. In contrast, Pi<sub>alk</sub> measurement variability due to repeated shims from the same muscle volume (0.40 ± 0.09mM; CV: 6.6%), and automated spectral processing (0.37 ± 0.01mM; CV: 2.3%), was minor. The quantification of Pi<sub>alk</sub> in skeletal muscle via surface coil 31P-MRS at 3 T demonstrated excellent reproducibility. However, caution is advised against placing the coil at the distal part of the quadriceps to mitigate shimming inhomogeneity.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2024-09-03
DOI
https://doi.org/10.1002/nbm.5255
Citations
2
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Repeatability of alkaline inorganic phosphate quantification in the skeletal muscle using 31P‐magnetic resonance spectroscopy at 3 T

Gwenaël Layec, Gaia Giuriato, David Bendahan, Alexs A. Matias et al.
2 citations
NMR in Biomedicine
Advanced MRI Techniques and Applications
0.81
article

Repeatability of alkaline inorganic phosphate quantification in the skeletal muscle using 31P‐magnetic resonance spectroscopy at 3 T

Gwenaël Layec, Gaia Giuriato, David Bendahan, Alexs A. Matias, Corinna Serviente, Yann Le Fur, Rajakumar Nagarajan, Stephen T. Decker, Muhammet Enes Erol
article en
2 citations

Abstract

The detection of a secondary inorganic phosphate (Pi) resonance, a possible marker of mitochondrial content in vivo, using phosphorus magnetic resonance spectroscopy (<sup>31</sup>P-MRS), poses technical challenges at 3 Tesla (T). Overcoming these challenges is imperative for the integration of this biomarker into clinical research. To evaluate the repeatability and reliability of measuring resting skeletal muscle alkaline Pi (Pi<sub>alk</sub>) using with <sup>31</sup>P-MRS at 3 T. After an initial set of experiments on five subjects to optimize the sequence, resting <sup>31</sup>P-MRS of the quadriceps muscles were acquired on two visits (~4 days apart) using an intra-subjects design, from 13 sedentary to moderately active young male and female adults (22 ± 3 years old) within a whole-body 3 T MR system. Measurement variability attributed to changes in coil position, shimming procedure, and spectral analysis were quantified. <sup>31</sup>P-MRS data were acquired with a <sup>31</sup>P/-proton (<sup>1</sup>H) dual-tuned surface coil positioned on the quadriceps using a pulse-acquire sequence. Test-retest absolute and relative repeatability was analyzed using the coefficient of variation (CV) and intra-class correlation coefficients (ICC), respectively. After sequence parameter optimization, Pi<sub>alk</sub> demonstrated high intra-subject repeatability (CV: 10.6 ± 5.4%, ICC: 0.80). Proximo-distal change in coil position along the length of the quadriceps introduced Pi<sub>alk</sub> quantitation variability (CV: 28 ± 5%), due to magnetic field inhomogeneity with more distal coil locations. In contrast, Pi<sub>alk</sub> measurement variability due to repeated shims from the same muscle volume (0.40 ± 0.09mM; CV: 6.6%), and automated spectral processing (0.37 ± 0.01mM; CV: 2.3%), was minor. The quantification of Pi<sub>alk</sub> in skeletal muscle via surface coil 31P-MRS at 3 T demonstrated excellent reproducibility. However, caution is advised against placing the coil at the distal part of the quadriceps to mitigate shimming inhomogeneity.

NMR in BiomedicineVol. 37(12)
University of Verona (IT), University of Nebraska at Omaha (US), University of Modena and Reggio Emilia (IT), Centre National de la Recherche Scientifique (FR), University of Utah (US), University of Massachusetts Amherst (US), Centre de Résonance Magnétique Biologique et Médicale (FR)
National Institutes of Health, National Heart, Lung, and Blood Institute
Openalex Percentile: Top 26%
Advanced MRI Techniques and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.