Repeatability of alkaline inorganic phosphate quantification in the skeletal muscle using <sup>31</sup>P‐magnetic resonance spectroscopy at 3 T
The detection of a secondary inorganic phosphate (Pi) resonance, a possible marker of mitochondrial content in vivo, using phosphorus magnetic resonance spectroscopy (<sup>31</sup>P-MRS), poses technical challenges at 3 Tesla (T). Overcoming these challenges is imperative for the integration of this biomarker into clinical research. To evaluate the repeatability and reliability of measuring resting skeletal muscle alkaline Pi (Pi<sub>alk</sub>) using with <sup>31</sup>P-MRS at 3 T. After an initial set of experiments on five subjects to optimize the sequence, resting <sup>31</sup>P-MRS of the quadriceps muscles were acquired on two visits (~4 days apart) using an intra-subjects design, from 13 sedentary to moderately active young male and female adults (22 ± 3 years old) within a whole-body 3 T MR system. Measurement variability attributed to changes in coil position, shimming procedure, and spectral analysis were quantified. <sup>31</sup>P-MRS data were acquired with a <sup>31</sup>P/-proton (<sup>1</sup>H) dual-tuned surface coil positioned on the quadriceps using a pulse-acquire sequence. Test-retest absolute and relative repeatability was analyzed using the coefficient of variation (CV) and intra-class correlation coefficients (ICC), respectively. After sequence parameter optimization, Pi<sub>alk</sub> demonstrated high intra-subject repeatability (CV: 10.6 ± 5.4%, ICC: 0.80). Proximo-distal change in coil position along the length of the quadriceps introduced Pi<sub>alk</sub> quantitation variability (CV: 28 ± 5%), due to magnetic field inhomogeneity with more distal coil locations. In contrast, Pi<sub>alk</sub> measurement variability due to repeated shims from the same muscle volume (0.40 ± 0.09mM; CV: 6.6%), and automated spectral processing (0.37 ± 0.01mM; CV: 2.3%), was minor. The quantification of Pi<sub>alk</sub> in skeletal muscle via surface coil 31P-MRS at 3 T demonstrated excellent reproducibility. However, caution is advised against placing the coil at the distal part of the quadriceps to mitigate shimming inhomogeneity.
Authors
- Gwenaël Layec (ORCID: https://orcid.org/0000-0002-5029-2457)
- Gaia Giuriato (ORCID: https://orcid.org/0000-0002-8149-9450)
- David Bendahan (ORCID: https://orcid.org/0000-0002-1502-0958)
- Alexs A. Matias (ORCID: https://orcid.org/0000-0003-2318-524X)
- Corinna Serviente (ORCID: https://orcid.org/0000-0003-3792-5480)
- Yann Le Fur
- Rajakumar Nagarajan (ORCID: https://orcid.org/0000-0001-7099-2816)
- Stephen T. Decker (ORCID: https://orcid.org/0000-0001-5867-1294)
- Muhammet Enes Erol (ORCID: https://orcid.org/0009-0006-1037-7399)
Institutions
- University of Verona (IT)
- University of Nebraska at Omaha (US)
- University of Modena and Reggio Emilia (IT)
- Centre National de la Recherche Scientifique (FR)
- University of Utah (US)
- University of Massachusetts Amherst (US)
- Centre de Résonance Magnétique Biologique et Médicale (FR)
Publication Details
- Journal
- NMR in Biomedicine
- Published
- 2024-09-03
- DOI
- https://doi.org/10.1002/nbm.5255
- Citations
- 2
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.81
Funders
- National Institutes of Health
- National Heart, Lung, and Blood Institute