A Rapid Head Organ Localization System Based on Clinically Realistic Images: A 3D Two Step Progressive Registration Method with CVH Anatomical Knowledge Mapping

Rapid localization of ROI (Region of Interest) for tomographic medical images (TMIs) is an important foundation for efficient image reading, computer-aided education, and well-informed rights of patients. However, due to the multimodality of clinical TMIs, the complexity of anatomy, and the deformation of organs caused by diseases, it is difficult to have a universal and low-cost method for ROI organ localization. This article focuses on actual concerns of TMIs from medical students, engineers, interdisciplinary researchers, and patients, exploring a universal registration method between the clinical CT/MRI dataset and CVH (Chinese Visible Human) to locate the organ ROI in a low-cost and lightweight way. The proposed method is called Two-step Progressive Registration (TSPR), where the first registration adopts "eye-nose triangle" features to determine the spatial orientation, and the second registration adopts the circular contour to determine the spatial scale, ultimately achieving CVH anatomical knowledge automated mapping. Through experimentation with representative clinical TMIs, the registration results are capable of labeling the ROI in the images well and can adapt to the deformation problem of ROI, as well as local extremum problems that are prone to occur in inter-subject registration. Unlike the ideal requirements for TMIs' data quality in laboratory research, TSPR has good adaptability to incomplete and non-thin-layer quality in real clinical data in a low-cost and lightweight way. This helps medical students, engineers, and interdisciplinary researchers independently browse images, receive computer-aided education, and provide patients with better access to well-informed services, highlighting the potential of digital public health and medical education.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2024-09-01
DOI
https://doi.org/10.3390/bioengineering11090891
Citations
2
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Rapid Head Organ Localization System Based on Clinically Realistic Images: A 3D Two Step Progressive Registration Method with CVH Anatomical Knowledge Mapping

Fei Tong, Mingguo Qiu, Yi Wu, Junjie Luo et al.
2 citations
Bioengineering
Medical Imaging and Analysis
0.37
article

A Rapid Head Organ Localization System Based on Clinically Realistic Images: A 3D Two Step Progressive Registration Method with CVH Anatomical Knowledge Mapping

Fei Tong, Mingguo Qiu, Yi Wu, Junjie Luo, Wenjing Wu, Liang Qiao, Zhongwen Luo, Changjin Sun, Yuting Wang, Yan Gong, Mingwen Ou
article en
2 citations

Abstract

Rapid localization of ROI (Region of Interest) for tomographic medical images (TMIs) is an important foundation for efficient image reading, computer-aided education, and well-informed rights of patients. However, due to the multimodality of clinical TMIs, the complexity of anatomy, and the deformation of organs caused by diseases, it is difficult to have a universal and low-cost method for ROI organ localization. This article focuses on actual concerns of TMIs from medical students, engineers, interdisciplinary researchers, and patients, exploring a universal registration method between the clinical CT/MRI dataset and CVH (Chinese Visible Human) to locate the organ ROI in a low-cost and lightweight way. The proposed method is called Two-step Progressive Registration (TSPR), where the first registration adopts "eye-nose triangle" features to determine the spatial orientation, and the second registration adopts the circular contour to determine the spatial scale, ultimately achieving CVH anatomical knowledge automated mapping. Through experimentation with representative clinical TMIs, the registration results are capable of labeling the ROI in the images well and can adapt to the deformation problem of ROI, as well as local extremum problems that are prone to occur in inter-subject registration. Unlike the ideal requirements for TMIs' data quality in laboratory research, TSPR has good adaptability to incomplete and non-thin-layer quality in real clinical data in a low-cost and lightweight way. This helps medical students, engineers, and interdisciplinary researchers independently browse images, receive computer-aided education, and provide patients with better access to well-informed services, highlighting the potential of digital public health and medical education.

BioengineeringVol. 11(9)
Army Medical University (CN), Southwest Hospital (CN)
Natural Science Foundation of Chongqing, Army Medical University, Centre Scientifique et Technique du Bâtiment, Chongqing Graduate Student Research Innovation Project
Quality Education
Openalex Percentile: Top 44%
Medical Imaging and Analysis
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.