Highly Sensitive Determination of Cadmium by Atomic Emission Spectrometry with Miniaturized Solution Anode Glow Discharge

A solution anode glow discharge (SAGD) was established as a miniaturized excitation source of atomic emission spectrometry (AES) for the detection of Cd in rhizosphere soil, carrot, and carrot leaf samples. The working conditions, such as electrolyte pH, discharge voltage, support electrolyte, solution flow rate, and discharge distance, were systematically optimized. The effect of 31 foreign ions on the Cd determination was investigated. In addition, the influences of matrix modifiers on the Cd signal intensity and interference elimination were examined in detail. The results showed that under the optimal operating parameters, the presence of Fe3+, Co2+, Pb2+, Cu2+, Cr3+, and Tl3+ ions at 30 mg/L causes severe depression effects for the detection of Cd, and adding ascorbic acid as a matrix modifier can reduce the matrix interference, improve sensitivity, and lower the limit of detection (LOD). The LOD of Cd is 4.4 μg/L, and power is below 8 W using SAGD without any matrix modifier. Compared with the solution cathode glow discharge–atomic emission spectrometry (SCGD-AES), the sensitivity is improved about 11-fold, and the power is consumed only about one-sixth. The analysis results of SAGD-AES are in agreement with the Cd-certified reference material and verification values measured by inductively coupled plasma atomic emission spectroscopy, suggesting that proposed method has high accuracy and reliability.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2024-09-01
DOI
https://doi.org/10.1134/s106193482470059x
Citations
2
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly Sensitive Determination of Cadmium by Atomic Emission Spectrometry with Miniaturized Solution Anode Glow Discharge

Quanfang Lu, Lijuan Cui, Jie Yu, Xiaoxia Hao et al.
2 citations
Journal of Analytical Chemistry
Analytical chemistry methods development
0.47
article

Highly Sensitive Determination of Cadmium by Atomic Emission Spectrometry with Miniaturized Solution Anode Glow Discharge

Quanfang Lu, Lijuan Cui, Jie Yu, Xiaoxia Hao, Xuyi Wang
article en
2 citations

Abstract

A solution anode glow discharge (SAGD) was established as a miniaturized excitation source of atomic emission spectrometry (AES) for the detection of Cd in rhizosphere soil, carrot, and carrot leaf samples. The working conditions, such as electrolyte pH, discharge voltage, support electrolyte, solution flow rate, and discharge distance, were systematically optimized. The effect of 31 foreign ions on the Cd determination was investigated. In addition, the influences of matrix modifiers on the Cd signal intensity and interference elimination were examined in detail. The results showed that under the optimal operating parameters, the presence of Fe3+, Co2+, Pb2+, Cu2+, Cr3+, and Tl3+ ions at 30 mg/L causes severe depression effects for the detection of Cd, and adding ascorbic acid as a matrix modifier can reduce the matrix interference, improve sensitivity, and lower the limit of detection (LOD). The LOD of Cd is 4.4 μg/L, and power is below 8 W using SAGD without any matrix modifier. Compared with the solution cathode glow discharge–atomic emission spectrometry (SCGD-AES), the sensitivity is improved about 11-fold, and the power is consumed only about one-sixth. The analysis results of SAGD-AES are in agreement with the Cd-certified reference material and verification values measured by inductively coupled plasma atomic emission spectroscopy, suggesting that proposed method has high accuracy and reliability.

Journal of Analytical ChemistryVol. 79(9)
Northwest Normal University (CN)
Openalex Percentile: Top 42%
Analytical chemistry methods development
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.