A novel method for measuring electrolytic conductivity with a polarization impedance control function

The article presents an idealized model of the differential method utilized in conductometry to measure electrolytic conductivity (EC). It identifies the main drawback of the widely used differential method: the inability to control the influence of polarization impedance on EC measurement results. A criterion for the absence of error caused by polarization effects is proposed, involving equality between the ratios of resistance differences and cell constant differences. A novel method for EC measurement, termed the double differential method, is introduced. This method relies on repeated differential impedance measurements and incorporates an additional third impedance measurement of a virtual liquid column. The new approach enables the identification of polarization impedance influence on EC measurements and the calculation of measurement errors for correction. A 3 times lower type A measurement uncertainty value can be achieved by averaging the corrected results.

Authors

Institutions

Publication Details

Journal
Measurements infrastructure
Published
2024-09-01
DOI
https://doi.org/10.33955/v8(2024)-061
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel method for measuring electrolytic conductivity with a polarization impedance control function

Oleksii Stennik, A. A. Mikhal
Measurements infrastructure
Analytical Chemistry and Sensors
article

A novel method for measuring electrolytic conductivity with a polarization impedance control function

Oleksii Stennik, A. A. Mikhal
article en

Abstract

The article presents an idealized model of the differential method utilized in conductometry to measure electrolytic conductivity (EC). It identifies the main drawback of the widely used differential method: the inability to control the influence of polarization impedance on EC measurement results. A criterion for the absence of error caused by polarization effects is proposed, involving equality between the ratios of resistance differences and cell constant differences. A novel method for EC measurement, termed the double differential method, is introduced. This method relies on repeated differential impedance measurements and incorporates an additional third impedance measurement of a virtual liquid column. The new approach enables the identification of polarization impedance influence on EC measurements and the calculation of measurement errors for correction. A 3 times lower type A measurement uncertainty value can be achieved by averaging the corrected results.

Measurements infrastructure(8)
National Academy of Sciences of Ukraine (UA), Institute of Electrodynamics (UA), State Enterprise «All-Ukrainian State Research and Production Center for Standardization, Metrology, Certification and Consumers Rights Protection»
Openalex Percentile: Top 86%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A novel method for measuring electrolytic conductivity with a polarization impedance control function — Oleksii Stennik, A. A. Mikhal · Measurements infrastructure (2024) | TGRS Research Map | TGRS