Regarding the establishment of the anti-burn «Fenix-MS» bed conformity with the requirements of quality and safety standards

The standards that anti-burn beds must meet are given. The design of the domestically produced anti-burn «Phoenix-MS» bed, which has improved design and technological indicators, is briefly described. The main test results of this bed, obtained in the process of independent conformity assessment, are presented. Their analysis showed that the product meets quality standards and ensures the safety of patients and medical personnel during its operation in medical institutions. It is noted that the manufacturer needs to carry out a more complete clinical evaluation of the product, taking into account the strengthening of this requirement in the new EU Regulation 2017/745 on medical devices.

Authors

Institutions

Publication Details

Journal
Measurements infrastructure
Published
2024-09-01
DOI
https://doi.org/10.33955/v8(2024)-055
Primary Topic
Healthcare Systems and Public Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Regarding the establishment of the anti-burn «Fenix-MS» bed conformity with the requirements of quality and safety standards

Oleksandr Kuzmenko, Anatolii Starunskyi, Salekh Abdulin, Mykhailo Semenenko
Measurements infrastructure
Healthcare Systems and Public Health
article

Regarding the establishment of the anti-burn «Fenix-MS» bed conformity with the requirements of quality and safety standards

Oleksandr Kuzmenko, Anatolii Starunskyi, Salekh Abdulin, Mykhailo Semenenko
article en

Abstract

The standards that anti-burn beds must meet are given. The design of the domestically produced anti-burn «Phoenix-MS» bed, which has improved design and technological indicators, is briefly described. The main test results of this bed, obtained in the process of independent conformity assessment, are presented. Their analysis showed that the product meets quality standards and ensures the safety of patients and medical personnel during its operation in medical institutions. It is noted that the manufacturer needs to carry out a more complete clinical evaluation of the product, taking into account the strengthening of this requirement in the new EU Regulation 2017/745 on medical devices.

Measurements infrastructure(8)
State Enterprise «All-Ukrainian State Research and Production Center for Standardization, Metrology, Certification and Consumers Rights Protection»
Openalex Percentile: Top 78%
Healthcare Systems and Public Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Regarding the establishment of the anti-burn «Fenix-MS» bed conformity with the requirements of quality and safety standards — Oleksandr Kuzmenko, Anatolii Starunskyi, et al. · Measurements infrastructure (2024) | TGRS Research Map | TGRS