Does the Novel Dual Source Heat Pump (DSHP) Out-Perform the Ideal DSHP? Experimentation Versus Simulation of DSHP Based Thermodynamic Irreversibility of the Throttle Valve

Purpose: The air-source heat pumps are associated with continuous frosting problems. To ensure a more energy efficiency technology, the novel dual-source heat pump (DSHP) was developed. This article aims to confirm and compare the energy performance of the novel dual-source heat pump (DSHP) with the performance of an ideal heat pump. Methods: We applied an experimental analysis from an installed DSHP system with converters and other components to obtain the energy performance of the DSHP, while the performance of an ideal pump was obtained from simulation based on the theoretical algorithm of the basic principle of the thermodynamic irreversibility of the throttle valve. Results: We found that the Ideal (simulated) DSHP has a higher coefficient of performance (COP) than the installed (experimented) DSHP. The Ideal DSHP’s COP of 4.52 is higher than the Novel DSHP’s COP, which range from 1.78 (day 3) to 2.01 (day 1). The DSHP are power efficient, which reduces carbon emission from whatever power source that is been used. Implications: Energy efficiency in buildings has severe implications for global warmings and the need for sustainability. Because the modern ventilation system utilise energy from waste and heat recovery to power heating and cooling systems, the DSHP remains promising for future generations of building ventilation design. Originality/Value: The value of the study is because it completes an experiment that analyse the performance of the DSHP, comparing the outcomes with results from a simulation based on an Ideal system.

Authors

Institutions

Publication Details

Journal
Revista de Gestão Social e Ambiental
Published
2024-09-03
DOI
https://doi.org/10.24857/rgsa.v18n9-184
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Does the Novel Dual Source Heat Pump (DSHP) Out-Perform the Ideal DSHP? Experimentation Versus Simulation of DSHP Based Thermodynamic Irreversibility of the Throttle Valve

Adedeji Daniel Gbadebo, Edwin King Ehiorobo
Revista de Gestão Social e Ambiental
Refrigeration and Air Conditioning Technologies
article

Does the Novel Dual Source Heat Pump (DSHP) Out-Perform the Ideal DSHP? Experimentation Versus Simulation of DSHP Based Thermodynamic Irreversibility of the Throttle Valve

Adedeji Daniel Gbadebo, Edwin King Ehiorobo
article en

Abstract

Purpose: The air-source heat pumps are associated with continuous frosting problems. To ensure a more energy efficiency technology, the novel dual-source heat pump (DSHP) was developed. This article aims to confirm and compare the energy performance of the novel dual-source heat pump (DSHP) with the performance of an ideal heat pump. Methods: We applied an experimental analysis from an installed DSHP system with converters and other components to obtain the energy performance of the DSHP, while the performance of an ideal pump was obtained from simulation based on the theoretical algorithm of the basic principle of the thermodynamic irreversibility of the throttle valve. Results: We found that the Ideal (simulated) DSHP has a higher coefficient of performance (COP) than the installed (experimented) DSHP. The Ideal DSHP’s COP of 4.52 is higher than the Novel DSHP’s COP, which range from 1.78 (day 3) to 2.01 (day 1). The DSHP are power efficient, which reduces carbon emission from whatever power source that is been used. Implications: Energy efficiency in buildings has severe implications for global warmings and the need for sustainability. Because the modern ventilation system utilise energy from waste and heat recovery to power heating and cooling systems, the DSHP remains promising for future generations of building ventilation design. Originality/Value: The value of the study is because it completes an experiment that analyse the performance of the DSHP, comparing the outcomes with results from a simulation based on an Ideal system.

Revista de Gestão Social e AmbientalVol. 18(9)
Advanced Energy (United States) (US), Walter Sisulu University (ZA)
Affordable and clean energy
Openalex Percentile: Top 86%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Does the Novel Dual Source Heat Pump (DSHP) Out-Perform the Ideal DSHP? Experimentation Versus Simulation of DSHP Based Thermodynamic Irreversibility of the Throttle Valve — Adedeji Daniel Gbadebo, Edwin King Ehiorobo · Revista de Gestão Social e Ambiental (2024) | TGRS Research Map | TGRS