Recent advances and trends in optical devices and sensors for hydrogen peroxide detection

Hydrogen peroxide (H 2 O 2 ) is a critically important, vital biomarker and hence a highly relevant analyte in a broad range of bioanalytical applications. The most recent trends furthering the ability of its reliable, reproducible, and sensitive quantification include the development of non-biological enzyme mimics, the investigation of smartphone cameras as transducers and detectors, and the continued development of semi-reversible and reversible detection strategies. While the non-biological catalysts offer stability-related advantages over enzymes while providing equally good limits of detection, critical questions regarding toxicity, persistence, (bio)accumulation, and overall environmental footprint need to be answered. In the case of heavy metal-based strategies a replacement by non-toxic, renewable alternatives should be an obvious research need. Signal recording has seen a dramatic change toward smartphones, with their ever-improving computing and image-acquisition abilities. Yet, with the sheer number of different camera and phone models progress can be difficult to assess, as reproducibility and comparability of results and experimental set-ups are too often elusive. In the area of semi-reversible sensors flow injection analysis (FIA) coupled with chemiluminescence (CL) remains the most advanced system. In the case of fully reversible sensors, research points toward oxygen-based sensing to be the most reliable. Analyzing publications from 2018 to 2024, it is not surprising that the important analytical figures of merit of low limits of detection (LODs), broad quantitation ranges, faster response and regeneration times combined with novel (reversible) probes continue to be and should remain central focus of future developments. • We highlight the relevance of hydrogen peroxide as versatile (bio)analyte. • We review the advance of optical sensors and (single-use) devices for the detection of hydrogen peroxide. • We discuss challenges and give an outlook on possible developments and future trends.

Authors

Institutions

Publication Details

Journal
TrAC Trends in Analytical Chemistry
Published
2024-09-03
DOI
https://doi.org/10.1016/j.trac.2024.117948
Citations
21
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
4.38
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Recent advances and trends in optical devices and sensors for hydrogen peroxide detection

Axel Duerkop, Antje J. Baeumner, John J. Galligan
21 citations
TrAC Trends in Analytical Chemistry
Electrochemical sensors and biosensors
4.38
article

Recent advances and trends in optical devices and sensors for hydrogen peroxide detection

Axel Duerkop, Antje J. Baeumner, John J. Galligan
article en
21 citations

Abstract

Hydrogen peroxide (H 2 O 2 ) is a critically important, vital biomarker and hence a highly relevant analyte in a broad range of bioanalytical applications. The most recent trends furthering the ability of its reliable, reproducible, and sensitive quantification include the development of non-biological enzyme mimics, the investigation of smartphone cameras as transducers and detectors, and the continued development of semi-reversible and reversible detection strategies. While the non-biological catalysts offer stability-related advantages over enzymes while providing equally good limits of detection, critical questions regarding toxicity, persistence, (bio)accumulation, and overall environmental footprint need to be answered. In the case of heavy metal-based strategies a replacement by non-toxic, renewable alternatives should be an obvious research need. Signal recording has seen a dramatic change toward smartphones, with their ever-improving computing and image-acquisition abilities. Yet, with the sheer number of different camera and phone models progress can be difficult to assess, as reproducibility and comparability of results and experimental set-ups are too often elusive. In the area of semi-reversible sensors flow injection analysis (FIA) coupled with chemiluminescence (CL) remains the most advanced system. In the case of fully reversible sensors, research points toward oxygen-based sensing to be the most reliable. Analyzing publications from 2018 to 2024, it is not surprising that the important analytical figures of merit of low limits of detection (LODs), broad quantitation ranges, faster response and regeneration times combined with novel (reversible) probes continue to be and should remain central focus of future developments. • We highlight the relevance of hydrogen peroxide as versatile (bio)analyte. • We review the advance of optical sensors and (single-use) devices for the detection of hydrogen peroxide. • We discuss challenges and give an outlook on possible developments and future trends.

TrAC Trends in Analytical ChemistryVol. 180
Czech Academy of Sciences, Institute of Analytical Chemistry (CZ), University of Regensburg (DE)
Affordable and clean energy
Openalex Percentile: Top 5%
Electrochemical sensors and biosensors
4.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.