Parametric Based Techno‐Economic Evaluation for a Solar Thermal‐<scp>PV</scp> Integrated Multi‐Commodity Storage Facility

ABSTRACT Postharvest losses and spoilage of agricultural products are a major problem for tropical countries, and it is even more challenging for countries encountering fluctuating power shortages, such as Pakistan. Therefore, this study focused on the energy and economic analysis of cold storage to store three products (potatoes, pomegranates, and potatoes) according to the season and storage span throughout the year. The cooling load of the cold store was supported by a LiBr‐H 2 O vapor absorption and vapor compression refrigeration system to maintain the desired temperature for each product during cold storage. A solar thermal PV system is installed to operate cold storage refrigeration systems. Cold storage performance was analyzed by developing thermal models of integrated systems using the ambient conditions of Lahore, Pakistan. A parametric study was also conducted to analyze the impact of various working parameters on integrated system performance, and it was found that the maximum peak cooling load of 91 kW inside cold storage is attributed to pomegranates owing to high ambient conditions during its loading month. The product loading rate significantly affects the cooling load of cold storage and varies directly with it, as observed for an increase in the product loading rate from 0 to 50 000 kg/day cooling load also increases from 34 to 87 kW. To meet the thermal demand of the generator of the vapor absorption system, parabolic troughs were installed to operate cold storage, and it was found that a minimum of four PTC were needed to support the peak cooling load at the maximum product loading rate and minimum DNI value. To meet the electrical demand of cold storage electrical equipment and the compressor of the vapor compression system, solar photovoltaic panels were installed, and it was found that a minimum of 618 panels was required at a minimum tilted radiation value. To validate the viability of proposed design system economic analysis was also conducted which revealed a payback period of 12 years for Kinnow and potatoes and 16 years for pomegranates.

Authors

Institutions

Publication Details

Journal
Energy Storage
Published
2024-09-01
DOI
https://doi.org/10.1002/est2.70022
Citations
3
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.31

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parametric Based Techno‐Economic Evaluation for a Solar Thermal‐PV Integrated Multi‐Commodity Storage Facility

Laveet Kumar, Abdul Ghafoor Memon, Malik Shahzaib, Abdul Moeez
3 citations
Energy Storage
Solar Thermal and Photovoltaic Systems
0.31
article

Parametric Based Techno‐Economic Evaluation for a Solar Thermal‐PV Integrated Multi‐Commodity Storage Facility

Laveet Kumar, Abdul Ghafoor Memon, Malik Shahzaib, Abdul Moeez
article en
3 citations

Abstract

ABSTRACT Postharvest losses and spoilage of agricultural products are a major problem for tropical countries, and it is even more challenging for countries encountering fluctuating power shortages, such as Pakistan. Therefore, this study focused on the energy and economic analysis of cold storage to store three products (potatoes, pomegranates, and potatoes) according to the season and storage span throughout the year. The cooling load of the cold store was supported by a LiBr‐H 2 O vapor absorption and vapor compression refrigeration system to maintain the desired temperature for each product during cold storage. A solar thermal PV system is installed to operate cold storage refrigeration systems. Cold storage performance was analyzed by developing thermal models of integrated systems using the ambient conditions of Lahore, Pakistan. A parametric study was also conducted to analyze the impact of various working parameters on integrated system performance, and it was found that the maximum peak cooling load of 91 kW inside cold storage is attributed to pomegranates owing to high ambient conditions during its loading month. The product loading rate significantly affects the cooling load of cold storage and varies directly with it, as observed for an increase in the product loading rate from 0 to 50 000 kg/day cooling load also increases from 34 to 87 kW. To meet the thermal demand of the generator of the vapor absorption system, parabolic troughs were installed to operate cold storage, and it was found that a minimum of four PTC were needed to support the peak cooling load at the maximum product loading rate and minimum DNI value. To meet the electrical demand of cold storage electrical equipment and the compressor of the vapor compression system, solar photovoltaic panels were installed, and it was found that a minimum of 618 panels was required at a minimum tilted radiation value. To validate the viability of proposed design system economic analysis was also conducted which revealed a payback period of 12 years for Kinnow and potatoes and 16 years for pomegranates.

Energy StorageVol. 6(6)
Mehran University of Engineering and Technology (PK), Qatar University (QA)
Qatar National Library
Affordable and clean energy
Openalex Percentile: Top 53%
Solar Thermal and Photovoltaic Systems
0.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.