Determination of saturation of the magnetic circuit of current transformer based on continuous measurement of impedance of the magnetization circuit

Saturation of electromagnetic current transformers in transient modes of operation of an electric power system can lead to incorrect operation of relay protection devices. One of the most promising directions to improve the stability of the operation of relay protection devices in such modes is digital correction of secondary current. Currently, effective methods have been developed to restore the secondary current based on determination of magnetic circuit saturation. However, the practical application of these methods is impossible due to the imperfection of existing methods of secondary current segmentation. Thus, it is urgent to develop a method to determine saturation for implementation of digital correction algorithms for electromagnetic current transformers. To solve the stated problem, methods of mathematical modeling of electrical circuits containing transformers and the small-disturbance theory have been used. Verification of the research results is carried out in the Matlab software package. A mathematical criterion is formulated to determine the saturation of the magnetic circuit of an electromagnetic current transformer based on the inductance of the magnetization circuit. A method of segmentation of the secondary current has been developed for the implementation of digital correction algorithms based on the proposed criterion. The effectiveness of the developed method to determine the saturation of the magnetic circuit of an electromagnetic current transformer using computational experiments in the Matlab software package is demonstrated. It is planned to verify the developed method using a physical model of an electromagnetic current transformer.

Authors

Institutions

Publication Details

Journal
Vestnik IGEU
Published
2024-08-31
DOI
https://doi.org/10.17588/2072-2672.2024.4.053-063
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of saturation of the magnetic circuit of current transformer based on continuous measurement of impedance of the magnetization circuit

D.Yu. Vikharev, A.Yu. Murzin, N.A. Rodin, R.D. Aysin
Vestnik IGEU
Electric Power Systems and Control
article

Determination of saturation of the magnetic circuit of current transformer based on continuous measurement of impedance of the magnetization circuit

D.Yu. Vikharev, A.Yu. Murzin, N.A. Rodin, R.D. Aysin
article en

Abstract

Saturation of electromagnetic current transformers in transient modes of operation of an electric power system can lead to incorrect operation of relay protection devices. One of the most promising directions to improve the stability of the operation of relay protection devices in such modes is digital correction of secondary current. Currently, effective methods have been developed to restore the secondary current based on determination of magnetic circuit saturation. However, the practical application of these methods is impossible due to the imperfection of existing methods of secondary current segmentation. Thus, it is urgent to develop a method to determine saturation for implementation of digital correction algorithms for electromagnetic current transformers. To solve the stated problem, methods of mathematical modeling of electrical circuits containing transformers and the small-disturbance theory have been used. Verification of the research results is carried out in the Matlab software package. A mathematical criterion is formulated to determine the saturation of the magnetic circuit of an electromagnetic current transformer based on the inductance of the magnetization circuit. A method of segmentation of the secondary current has been developed for the implementation of digital correction algorithms based on the proposed criterion. The effectiveness of the developed method to determine the saturation of the magnetic circuit of an electromagnetic current transformer using computational experiments in the Matlab software package is demonstrated. It is planned to verify the developed method using a physical model of an electromagnetic current transformer.

Vestnik IGEU(4)
Ivanovo State Power University (RU)
Affordable and clean energy
Openalex Percentile: Top 88%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.