PbS-based SWIR micro-spectrometer with on-chip Fabry–Perot filter array

Miniaturized and portable on-chip spectrometers have been widely explored to facilitate many applications including chemical analysis, environmental monitoring, medical diagnostics, and astronomical observations. However, the optical spectra of micro-spectrometers are mostly within the visible range. Here, we develop high-performance short-wave infrared (SWIR) micro-spectrometers through the integration of wafer-scale uniform lead sulfide (PbS) thin films with an on-chip Fabry-Perot filter array. The optoelectronic performance of PbS-based detectors could be markedly improved through the optimization of chemical bath deposition (CBD) conditions. The high-sensitivity PbS detectors based on the Fabry-Perot filter array demonstrate chemical analysis application.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2024-09-03
DOI
https://doi.org/10.1364/ol.527883
Citations
2
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PbS-based SWIR micro-spectrometer with on-chip Fabry–Perot filter array

Ge Mu, Taipeng Li, Xin Tang, Qun Hao
2 citations
Optics Letters
Photonic and Optical Devices
0.42
article

PbS-based SWIR micro-spectrometer with on-chip Fabry–Perot filter array

Ge Mu, Taipeng Li, Xin Tang, Qun Hao
article en
2 citations

Abstract

Miniaturized and portable on-chip spectrometers have been widely explored to facilitate many applications including chemical analysis, environmental monitoring, medical diagnostics, and astronomical observations. However, the optical spectra of micro-spectrometers are mostly within the visible range. Here, we develop high-performance short-wave infrared (SWIR) micro-spectrometers through the integration of wafer-scale uniform lead sulfide (PbS) thin films with an on-chip Fabry-Perot filter array. The optoelectronic performance of PbS-based detectors could be markedly improved through the optimization of chemical bath deposition (CBD) conditions. The high-sensitivity PbS detectors based on the Fabry-Perot filter array demonstrate chemical analysis application.

Optics LettersVol. 49(19)
Beijing Institute of Technology (CN), Beijing Institute of Optoelectronic Technology (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China, Fundamental Research Funds for the Central Universities
Affordable and clean energy
Openalex Percentile: Top 38%
Photonic and Optical Devices
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

PbS-based SWIR micro-spectrometer with on-chip Fabry–Perot filter array — Ge Mu, Taipeng Li, et al. · Optics Letters (2024) | TGRS Research Map | TGRS