Universal centralized protection against single phase earth faults in 6–10 kV cable networks

Selective protection against single phase earth faults in distribution 6–10 kV cable networks can be performed both with the use of individual (per connection) and centralized devices covering all connections of the protected object. The advantages of centralized devices are reduction of specific (per connection) costs of protection, simplification of its operation and design. Well-known technical solutions in terms of centralized protection devices against this type of damage do not always provide versatility (the possibility to use neutral cables of 6–10 kV in various grounding modes) and high technical perfection (selectivity and stability of operation). Thus, it is relevant to develop a universal centralized protection against single-phase earth faults, ensuring high technical perfection for all types of earth faults in 6–10 kV cable networks with different neutral grounding modes. The authors have used a comprehensive simulation model "cable network – protection device" to study the selectivity and stability of the developed principles of implementation and algorithms for centralized protection against earth faults. The model is designed in SimPowerSystems and Simulink software. The configuration and parameters of the cable network model have been selected considering the key features of 6–10 kV distribution cable networks of industrial and urban power supply systems. A universal centralized protection against all types of earth faults in 6–10 kV cable networks with various neutral grounding modes has been developed. The results of functional tests on the simulation model have confirmed the effectiveness of the developed algorithms of the developed centralized protection for all types of earth faults both in uncompensated and compensated cable networks of 6–10 kV. The proposed technical solution implements a multifunctional multiparametric centralized protection against earth faults. It has such properties as versatility, selectivity, and high stability of operation for all types of earth faults, recognition of types of single-phase earth faults, continuity of action in stable and most dangerous arc intermittent earth faults.

Authors

Institutions

Publication Details

Journal
Vestnik IGEU
Published
2024-08-31
DOI
https://doi.org/10.17588/2072-2672.2024.4.041-052
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Universal centralized protection against single phase earth faults in 6–10 kV cable networks

A. A. Syomushkin, V.A. Shuin, T.Yu. Shadrikova, K.S. Aleshin
Vestnik IGEU
Power Systems Fault Detection
article

Universal centralized protection against single phase earth faults in 6–10 kV cable networks

A. A. Syomushkin, V.A. Shuin, T.Yu. Shadrikova, K.S. Aleshin
article en

Abstract

Selective protection against single phase earth faults in distribution 6–10 kV cable networks can be performed both with the use of individual (per connection) and centralized devices covering all connections of the protected object. The advantages of centralized devices are reduction of specific (per connection) costs of protection, simplification of its operation and design. Well-known technical solutions in terms of centralized protection devices against this type of damage do not always provide versatility (the possibility to use neutral cables of 6–10 kV in various grounding modes) and high technical perfection (selectivity and stability of operation). Thus, it is relevant to develop a universal centralized protection against single-phase earth faults, ensuring high technical perfection for all types of earth faults in 6–10 kV cable networks with different neutral grounding modes. The authors have used a comprehensive simulation model "cable network – protection device" to study the selectivity and stability of the developed principles of implementation and algorithms for centralized protection against earth faults. The model is designed in SimPowerSystems and Simulink software. The configuration and parameters of the cable network model have been selected considering the key features of 6–10 kV distribution cable networks of industrial and urban power supply systems. A universal centralized protection against all types of earth faults in 6–10 kV cable networks with various neutral grounding modes has been developed. The results of functional tests on the simulation model have confirmed the effectiveness of the developed algorithms of the developed centralized protection for all types of earth faults both in uncompensated and compensated cable networks of 6–10 kV. The proposed technical solution implements a multifunctional multiparametric centralized protection against earth faults. It has such properties as versatility, selectivity, and high stability of operation for all types of earth faults, recognition of types of single-phase earth faults, continuity of action in stable and most dangerous arc intermittent earth faults.

Vestnik IGEU(4)
Ivanovo State Power University (RU)
Sustainable cities and communities
Openalex Percentile: Top 85%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.