Optimized automated blood cells analysis using Enhanced Greywolf Optimization with integrated attention mechanism and YOLOv5

Blood testing is widely regarded as a fundamental diagnostic procedure in healthcare, with blood cell counting being particularly vital for diagnosing conditions and evaluating overall health. Traditional methods employing hemocytometers and diverse laboratory instruments are typically employed to conduct blood counts manually. Using a microscope, manually counting, and examining blood cells takes time and effort. Thus, developing autonomous blood cells detecting and counting cells in this system becomes necessary to help doctors diagnose patients quickly and accurately. The proposed method integrates the YOLOv5 object detection framework with Enhanced Graywolf Optimization (EGWO) and an Attention Mechanism to improve the accuracy and efficiency of RBC detection. The YOLOv5 architecture is optimized for the task through the EGWO algorithm, which fine-tunes the model parameters, while the Attention Mechanism focuses on extracting critical features from blood cell images. The model is trained and validated using the BCCD dataset, employing an 80/20 split for training and validation. Data augmentation techniques, such as random rotations, flips, and color adjustments, are applied to enhance model generalization. Experimental results demonstrate that our method achieves a high accuracy of 99.89 %, outperforming existing models like Faster R-CNN, CNN, and DCNN regarding accuracy, training time, and inference speed. The proposed method's moderate complexity and fast inference time make it suitable for real-time applications in clinical settings. This research provides a robust and efficient solution for automated RBC detection and counting, with potential implications for improving diagnostic processes in hematological analyses. Overall, in practical applications, it is helpful for counting red blood cells from smeared pictures in less than a second.

Authors

Institutions

Publication Details

Journal
Alexandria Engineering Journal
Published
2024-09-03
DOI
https://doi.org/10.1016/j.aej.2024.08.054
Citations
5
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
1.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized automated blood cells analysis using Enhanced Greywolf Optimization with integrated attention mechanism and YOLOv5

Lassaad Ben Ammar, Moez Krichen, Meznah A. Alamro, Karim Gasmi et al.
5 citations
Alexandria Engineering Journal
Digital Imaging for Blood Diseases
1.25
article

Optimized automated blood cells analysis using Enhanced Greywolf Optimization with integrated attention mechanism and YOLOv5

Lassaad Ben Ammar, Moez Krichen, Meznah A. Alamro, Karim Gasmi, Alaeddine Mihoub, Osama R. Shahin, Mohammed Abdullah Tawashi
article en
5 citations

Abstract

Blood testing is widely regarded as a fundamental diagnostic procedure in healthcare, with blood cell counting being particularly vital for diagnosing conditions and evaluating overall health. Traditional methods employing hemocytometers and diverse laboratory instruments are typically employed to conduct blood counts manually. Using a microscope, manually counting, and examining blood cells takes time and effort. Thus, developing autonomous blood cells detecting and counting cells in this system becomes necessary to help doctors diagnose patients quickly and accurately. The proposed method integrates the YOLOv5 object detection framework with Enhanced Graywolf Optimization (EGWO) and an Attention Mechanism to improve the accuracy and efficiency of RBC detection. The YOLOv5 architecture is optimized for the task through the EGWO algorithm, which fine-tunes the model parameters, while the Attention Mechanism focuses on extracting critical features from blood cell images. The model is trained and validated using the BCCD dataset, employing an 80/20 split for training and validation. Data augmentation techniques, such as random rotations, flips, and color adjustments, are applied to enhance model generalization. Experimental results demonstrate that our method achieves a high accuracy of 99.89 %, outperforming existing models like Faster R-CNN, CNN, and DCNN regarding accuracy, training time, and inference speed. The proposed method's moderate complexity and fast inference time make it suitable for real-time applications in clinical settings. This research provides a robust and efficient solution for automated RBC detection and counting, with potential implications for improving diagnostic processes in hematological analyses. Overall, in practical applications, it is helpful for counting red blood cells from smeared pictures in less than a second.

Alexandria Engineering JournalVol. 109
Princess Nourah bint Abdulrahman University (SA), Prince Sattam Bin Abdulaziz University (SA), University of Sfax (TN), Qassim University (SA), Jouf University (SA), Al Baha University (SA), Helwan University (EG)
Prince Sattam bin Abdulaziz University, Princess Nourah Bint Abdulrahman University
Openalex Percentile: Top 19%
Digital Imaging for Blood Diseases
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.