The Effect of Gate Drive Resistance on the CM EMI Performance of the Balanced Inverter With Asymmetrical Parasitic Impedance Distribution

This paper presents an investigation of the effects of the gate drive resistance on the performance of the balanced inverter used for common-mode voltage cancellation. A simplified analytical common-mode voltage model that incorporates the circuit stray inductances is derived to capture the impact of the gate drive resistance on the effectiveness of common-mode voltage cancellation during switching transients. Experiments with different gate drive resistance have been implemented to evaluate the proposed analytical model on a 30-kW hardware demonstrator unit. The experimental results show raising the gate resistance from 4 Ω to 8 Ω reduces the peak value of the source common-mode voltage frequency spectrum by approx. 6 dB, and the inverter power loss increases by approx. 54%, highlighting the performance tradeoffs associated with this technique.

Authors

Publication Details

Journal
IEEE Transactions on Industry Applications
Published
2024-08-20
DOI
https://doi.org/10.1109/tia.2024.3446748
Citations
2
Primary Topic
Electromagnetic Compatibility and Noise Suppression
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Gate Drive Resistance on the CM EMI Performance of the Balanced Inverter With Asymmetrical Parasitic Impedance Distribution

Thomas M. Jahns, Bulent Sarlioglu, Pengkun Tian, Feida Chen
2 citations
IEEE Transactions on Industry Applications
Electromagnetic Compatibility and Noise Suppression
0.42
article

The Effect of Gate Drive Resistance on the CM EMI Performance of the Balanced Inverter With Asymmetrical Parasitic Impedance Distribution

Thomas M. Jahns, Bulent Sarlioglu, Pengkun Tian, Feida Chen
article en
2 citations

Abstract

This paper presents an investigation of the effects of the gate drive resistance on the performance of the balanced inverter used for common-mode voltage cancellation. A simplified analytical common-mode voltage model that incorporates the circuit stray inductances is derived to capture the impact of the gate drive resistance on the effectiveness of common-mode voltage cancellation during switching transients. Experiments with different gate drive resistance have been implemented to evaluate the proposed analytical model on a 30-kW hardware demonstrator unit. The experimental results show raising the gate resistance from 4 Ω to 8 Ω reduces the peak value of the source common-mode voltage frequency spectrum by approx. 6 dB, and the inverter power loss increases by approx. 54%, highlighting the performance tradeoffs associated with this technique.

IEEE Transactions on Industry ApplicationsVol. 60(6)
Wisconsin Alumni Research Foundation, Wisconsin Electric Machines and Power Electronics Consortium
Affordable and clean energy
Openalex Percentile: Top 38%
Electromagnetic Compatibility and Noise Suppression
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Effect of Gate Drive Resistance on the CM EMI Performance of the Balanced Inverter With Asymmetrical Parasitic Impedance Distribution — Thomas M. Jahns, Bulent Sarlioglu, et al. · IEEE Transactions on Industry Applications (2024) | TGRS Research Map | TGRS