Suppressing Spatial Inhomogeneity in Spin Polarization and Light Shift in Atomic Magnetometer Array Using Frequency-Paired Counter-Propagating Pumps

In spin-exchange-relaxation-free (SERF) atomic magnetometers (AMs), the attenuation of circularly polarized pump beam introduces spatial-dependent artificial magnetic fields in atomic spin polarization and light shift. In general, such a spatial-dependent effective magnetic field, especially prevalent in single-cell magnetometer arrays, cannot be uniformly compensated over the entire excitation region, resulting in a complex distributed compensation mask effect. In addition, any external effective-field-compensation methods inevitably complicate the final analysis of the unknown magnetic field measured. Here, we report a new excitation scheme that can substantially suppress spatial nonuniformity due to pump beam attenuation. Using counter-propagating pump beams with symmetrically red- and blue-detuning-paired frequencies, we demonstrate a significant reduction of spatial inhomogeneity in atomic spin polarization and light shift in comparison with the usual single-frequency unidirection and counter-propagating pump schemes. Employing this red-/blue-detuning-paired pump scheme, we construct a single-cell, four-channel SERF magnetometer array with high spatial homogeneity. We demonstrate ~10-fT/Hz<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{{1}/{2}}$ </tex-math></inline-formula> sensitivity in the 5–45-Hz band for all four channels, with a gradient sensitivity of 2 fT/Hz1/2<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{{1}/{2}}$ </tex-math></inline-formula>/cm in the same band. This new scheme enables the development of single-vapor-cell, high-uniformity multichannel magnetic field mapping devices with potential applications in magnetoencephalography (MEG) and magnetocardiography (MCG), or in searching for exotic spin-dependent interactions.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-08-20
DOI
https://doi.org/10.1109/jsen.2024.3443284
Citations
5
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
1.69

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Suppressing Spatial Inhomogeneity in Spin Polarization and Light Shift in Atomic Magnetometer Array Using Frequency-Paired Counter-Propagating Pumps

Runbing Li, Yuanjiang Tang, Mingsheng Zhan, An‐Ning Xu et al.
5 citations
IEEE Sensors Journal
Atomic and Subatomic Physics Research
1.69
article

Suppressing Spatial Inhomogeneity in Spin Polarization and Light Shift in Atomic Magnetometer Array Using Frequency-Paired Counter-Propagating Pumps

Runbing Li, Yuanjiang Tang, Mingsheng Zhan, An‐Ning Xu, Bei Liu, Peng Jin, Yong‐Chun Liu, L. Deng
article en
5 citations

Abstract

In spin-exchange-relaxation-free (SERF) atomic magnetometers (AMs), the attenuation of circularly polarized pump beam introduces spatial-dependent artificial magnetic fields in atomic spin polarization and light shift. In general, such a spatial-dependent effective magnetic field, especially prevalent in single-cell magnetometer arrays, cannot be uniformly compensated over the entire excitation region, resulting in a complex distributed compensation mask effect. In addition, any external effective-field-compensation methods inevitably complicate the final analysis of the unknown magnetic field measured. Here, we report a new excitation scheme that can substantially suppress spatial nonuniformity due to pump beam attenuation. Using counter-propagating pump beams with symmetrically red- and blue-detuning-paired frequencies, we demonstrate a significant reduction of spatial inhomogeneity in atomic spin polarization and light shift in comparison with the usual single-frequency unidirection and counter-propagating pump schemes. Employing this red-/blue-detuning-paired pump scheme, we construct a single-cell, four-channel SERF magnetometer array with high spatial homogeneity. We demonstrate ~10-fT/Hz<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{{1}/{2}}$ </tex-math></inline-formula> sensitivity in the 5–45-Hz band for all four channels, with a gradient sensitivity of 2 fT/Hz1/2<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{{1}/{2}}$ </tex-math></inline-formula>/cm in the same band. This new scheme enables the development of single-vapor-cell, high-uniformity multichannel magnetic field mapping devices with potential applications in magnetoencephalography (MEG) and magnetocardiography (MCG), or in searching for exotic spin-dependent interactions.

IEEE Sensors JournalVol. 24(19)
Shandong University (CN), Tsinghua University (CN)
National Natural Science Foundation of China, Fundamental Research Fund of Shandong University
Affordable and clean energy
Openalex Percentile: Top 16%
Atomic and Subatomic Physics Research
1.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.