Large area kidney imaging for pre-transplant evaluation using real-time robotic optical coherence tomography

Optical coherence tomography (OCT) can be used to image microstructures of human kidneys. However, current OCT probes exhibit inadequate field-of-view, leading to potentially biased kidney assessment. Here we present a robotic OCT system where the probe is integrated to a robot manipulator, enabling wider area (covers an area of 106.39 mm by 37.70 mm) spatially-resolved imaging. Our system comprehensively scans the kidney surface at the optimal altitude with preoperative path planning and OCT image-based feedback control scheme. It further parameterizes and visualizes microstructures of large area. We verified the system positioning accuracy on a phantom as 0.0762 ± 0.0727 mm and showed the clinical feasibility by scanning ex vivo kidneys. The parameterization reveals vasculatures beneath the kidney surface. Quantification on the proximal convoluted tubule of a human kidney yields clinical-relevant information. The system promises to assess kidney viability for transplantation after collecting a vast amount of whole-organ parameterization and patient outcomes data.

Authors

Institutions

Publication Details

Journal
Communications Engineering
Published
2024-09-02
DOI
https://doi.org/10.1038/s44172-024-00264-7
Citations
15
Primary Topic
Renal and Vascular Pathologies
Type
article
Field-Weighted Citation Impact
6.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Large area kidney imaging for pre-transplant evaluation using real-time robotic optical coherence tomography

Mousa Moradi, Yu Chen, Xihan Ma, Moshe Levi et al.
15 citations
Communications Engineering
Renal and Vascular Pathologies
6.28
article

Large area kidney imaging for pre-transplant evaluation using real-time robotic optical coherence tomography

Mousa Moradi, Yu Chen, Xihan Ma, Moshe Levi, Qinggong Tang, Haichong K. Zhang, Xiaoyu Ma
article en
15 citations

Abstract

Optical coherence tomography (OCT) can be used to image microstructures of human kidneys. However, current OCT probes exhibit inadequate field-of-view, leading to potentially biased kidney assessment. Here we present a robotic OCT system where the probe is integrated to a robot manipulator, enabling wider area (covers an area of 106.39 mm by 37.70 mm) spatially-resolved imaging. Our system comprehensively scans the kidney surface at the optimal altitude with preoperative path planning and OCT image-based feedback control scheme. It further parameterizes and visualizes microstructures of large area. We verified the system positioning accuracy on a phantom as 0.0762 ± 0.0727 mm and showed the clinical feasibility by scanning ex vivo kidneys. The parameterization reveals vasculatures beneath the kidney surface. Quantification on the proximal convoluted tubule of a human kidney yields clinical-relevant information. The system promises to assess kidney viability for transplantation after collecting a vast amount of whole-organ parameterization and patient outcomes data.

Communications EngineeringVol. 3(1)
Worcester Polytechnic Institute (US), Fujian Normal University (CN), Georgetown University (US), University of Massachusetts Amherst (US), University of Oklahoma (US)
National Institutes of Health, National Institute of General Medical Sciences
Openalex Percentile: Top 3%
Renal and Vascular Pathologies
6.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.