Establishment of a 241Am gamma calibration field based on international standards and its conversion coefficients

A 241Am gamma (γ)-ray calibration field that meets the requirements for a γ-ray reference field as specified in the ISO 4037 standard series was established in the Facility of Radiation Standards of the Japan Atomic Energy Agency. The reference air kerma rates were measured using a reference ionization chamber calibrated by the N-80 quality X-ray calibration field of the national metrology standard in Japan and with a correction to account for differences in photon energy due to the calibration field. Conversion coefficients for the 241Am γ-ray calibration field, including those not listed in the ISO 4037 standard series, were calculated based on the measured γ-ray fluence rate spectra.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2024-08-31
DOI
https://doi.org/10.1093/rpd/ncae186
Citations
3
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
1.82
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishment of a 241Am gamma calibration field based on international standards and its conversion coefficients

Munehiko Kowatari, Hiroshi Yoshitomi, Yoshihiko Tanimura, Tomoya Tsuji
3 citations
Radiation Protection Dosimetry
Nuclear Physics and Applications
1.82
article

Establishment of a 241Am gamma calibration field based on international standards and its conversion coefficients

Munehiko Kowatari, Hiroshi Yoshitomi, Yoshihiko Tanimura, Tomoya Tsuji
article en
3 citations

Abstract

A 241Am gamma (γ)-ray calibration field that meets the requirements for a γ-ray reference field as specified in the ISO 4037 standard series was established in the Facility of Radiation Standards of the Japan Atomic Energy Agency. The reference air kerma rates were measured using a reference ionization chamber calibrated by the N-80 quality X-ray calibration field of the national metrology standard in Japan and with a correction to account for differences in photon energy due to the calibration field. Conversion coefficients for the 241Am γ-ray calibration field, including those not listed in the ISO 4037 standard series, were calculated based on the measured γ-ray fluence rate spectra.

Radiation Protection DosimetryVol. 200(15)
Japan Atomic Energy Agency (JP), National Institutes for Quantum Science and Technology (JP)
Affordable and clean energy
Openalex Percentile: Top 16%
Nuclear Physics and Applications
1.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.