适形贴壁支架的“适形”与“可行”结构设计及其力学分析

To address the conflict between the “fitness” and “feasibility” of body-fitted stents, this paper investigates the impact of various smoothing design strategies on the mechanical behaviour and apposition performance of stent. Based on the three-dimensional projection method, the projection region was fitted with the least squares method (fitting orders 1–6 corresponded to models 1–6, respectively) to achieve the effect of smoothing the body-fitted stent. The simulation included the crimping and expansion process of six groups of stents in stenotic vessels with different degrees of plaque calcification. Various metrics were analyzed, including bending stiffness, stent ruggedness, area residual stenosis rate, contact area fraction, and contact volume fraction. The study findings showed that the bending stiffness, stent ruggedness, area residual stenosis rate, contact area fraction and contact volume fraction increased with the fitting order's increase. Model 1 had the smallest contact area fraction and contact volume fraction, 77.63% and 83.49% respectively, in the incompletely calcified plaque environment. In the completely calcified plaque environment, these values were 72.86% and 82.21%, respectively. Additionally, it had the worst “fitness”. Models 5 and 6 had similar values for stent ruggedness, with 32.15% and 32.38%, respectively, which indicated the worst "feasibility" for fabrication and implantation. Models 2, 3, and 4 had similar area residual stenosis rates in both plaque environments. In conclusion, it is more reasonable to obtain the body-fitted stent by using 2nd to 4th order fitting with the least squares method to the projected region. Among them, the body-fitted stent obtained by the 2nd order fitting performs better in the completely calcified environment.

Authors

Institutions

Publication Details

Journal
PubMed Central
Published
2024-08-25
DOI
https://doi.org/10.7507/1001-5515.202403005
Primary Topic
Peripheral Artery Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

适形贴壁支架的“适形”与“可行”结构设计及其力学分析

Jiling Feng, Keyi Tao, Aike Qiao, Shengwen Liu et al.
PubMed Central
Peripheral Artery Disease Management
article

适形贴壁支架的“适形”与“可行”结构设计及其力学分析

Jiling Feng, Keyi Tao, Aike Qiao, Shengwen Liu, Hao Sun, Tianming Du, Zhao Liu, Yanping Zhang
article en

Abstract

To address the conflict between the “fitness” and “feasibility” of body-fitted stents, this paper investigates the impact of various smoothing design strategies on the mechanical behaviour and apposition performance of stent. Based on the three-dimensional projection method, the projection region was fitted with the least squares method (fitting orders 1–6 corresponded to models 1–6, respectively) to achieve the effect of smoothing the body-fitted stent. The simulation included the crimping and expansion process of six groups of stents in stenotic vessels with different degrees of plaque calcification. Various metrics were analyzed, including bending stiffness, stent ruggedness, area residual stenosis rate, contact area fraction, and contact volume fraction. The study findings showed that the bending stiffness, stent ruggedness, area residual stenosis rate, contact area fraction and contact volume fraction increased with the fitting order's increase. Model 1 had the smallest contact area fraction and contact volume fraction, 77.63% and 83.49% respectively, in the incompletely calcified plaque environment. In the completely calcified plaque environment, these values were 72.86% and 82.21%, respectively. Additionally, it had the worst “fitness”. Models 5 and 6 had similar values for stent ruggedness, with 32.15% and 32.38%, respectively, which indicated the worst "feasibility" for fabrication and implantation. Models 2, 3, and 4 had similar area residual stenosis rates in both plaque environments. In conclusion, it is more reasonable to obtain the body-fitted stent by using 2nd to 4th order fitting with the least squares method to the projected region. Among them, the body-fitted stent obtained by the 2nd order fitting performs better in the completely calcified environment.

PubMed Central
Manchester Metropolitan University (GB), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Beijing University of Technology (CN), China International Science and Technology Cooperation (CN), Fu Wai Hospital (CN), Beijing University of Chemical Technology (CN), University of Science and Technology Beijing (CN)
Openalex Percentile: Top 73%
Peripheral Artery Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.