440. QUANTIFICATION OF FLUORESCENCE ANGIOGRAPHY FOR ESOPHAGEAL PERFUSION ASSESSMENT: MEASURING AGREEMENT BETWEEN TWO SOFTWARE ALGORITHMS

Abstract Background Indocyanine green fluorescence angiography (ICG-FA) may reduce perfusion related complications after esophagectomy with gastric conduit reconstruction. Software implementations for quantifying ICG-FA are emerging to overcome a subjective interpretation of the technology. Comparison between quantification algorithms is needed to judge its external validity. This study aimed to measure the agreement for esophageal perfusion assessment between two independently developed quantification software implementations. Methods This retrospective cohort analysis included standardized ICG-FA video recordings of patients who underwent esophagectomy with gastric conduit reconstruction between August 2020 until February 2022. Recordings were analysed by two quantification software implementations: AMS and CPH. The quantitative parameter used to measure visceral perfusion was the normalized maximum slope derived from fluorescence time curves. The agreement between AMS and CPH was evaluated in a Bland-Altman analysis. The relation between the intraoperative measurement of perfusion and the incidence of anastomotic leakage was determined for both software implementations. Results Seventy pre-anastomosis ICG-FA recordings were included in the study. The Bland-Altman analysis indicated a mean relative difference of +58.2% in the measurement of the normalized maximum slope when comparing the AMS software to CPH. The agreement between AMS and CPH deteriorated as the magnitude of the measured values increased, revealing a proportional (linear) bias (R2 = 0.512, p < .001). Neither the AMS nor the CPH measurements of the normalized maximum slope held a significant relationship with the occurrence of anastomotic leakage (median of 0.081 versus 0.074, p = 0.32 and 0.041 vs 0.042, p = 0.51, respectively). Divergent approaches in maximum slope determination and raw signal filtering were identified as contributing factors to the differences in outcome. Conclusion This is the first study to demonstrate technical differences in software implementations that can lead to discrepancies in ICG-FA quantification in human clinical cases. The possible variation among software-based quantification methods should be considered when interpreting studies that report quantitative ICG-FA parameters and derived thresholds, as there may be a limited external validity.

Authors

Institutions

Publication Details

Journal
Diseases of the Esophagus
Published
2024-09-01
DOI
https://doi.org/10.1093/dote/doae057.190
Primary Topic
Esophageal Cancer Research and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

440. QUANTIFICATION OF FLUORESCENCE ANGIOGRAPHY FOR ESOPHAGEAL PERFUSION ASSESSMENT: MEASURING AGREEMENT BETWEEN TWO SOFTWARE ALGORITHMS

Morten Bo Søndergaard Svendsen, Mark I. van Berge Henegouwen, Roel Hompes, Jens Osterkamp et al.
Diseases of the Esophagus
Esophageal Cancer Research and Treatment
article

440. QUANTIFICATION OF FLUORESCENCE ANGIOGRAPHY FOR ESOPHAGEAL PERFUSION ASSESSMENT: MEASURING AGREEMENT BETWEEN TWO SOFTWARE ALGORITHMS

Morten Bo Søndergaard Svendsen, Mark I. van Berge Henegouwen, Roel Hompes, Jens Osterkamp, Suzanne Sarah Gisbertz, Daniël M. de Bruin, Richard M. van den Elzen, Hanneke Joosten, Michael Patrick Achiam, David J. Nijssen, M Dalsgaard
article en

Abstract

Abstract Background Indocyanine green fluorescence angiography (ICG-FA) may reduce perfusion related complications after esophagectomy with gastric conduit reconstruction. Software implementations for quantifying ICG-FA are emerging to overcome a subjective interpretation of the technology. Comparison between quantification algorithms is needed to judge its external validity. This study aimed to measure the agreement for esophageal perfusion assessment between two independently developed quantification software implementations. Methods This retrospective cohort analysis included standardized ICG-FA video recordings of patients who underwent esophagectomy with gastric conduit reconstruction between August 2020 until February 2022. Recordings were analysed by two quantification software implementations: AMS and CPH. The quantitative parameter used to measure visceral perfusion was the normalized maximum slope derived from fluorescence time curves. The agreement between AMS and CPH was evaluated in a Bland-Altman analysis. The relation between the intraoperative measurement of perfusion and the incidence of anastomotic leakage was determined for both software implementations. Results Seventy pre-anastomosis ICG-FA recordings were included in the study. The Bland-Altman analysis indicated a mean relative difference of +58.2% in the measurement of the normalized maximum slope when comparing the AMS software to CPH. The agreement between AMS and CPH deteriorated as the magnitude of the measured values increased, revealing a proportional (linear) bias (R2 = 0.512, p < .001). Neither the AMS nor the CPH measurements of the normalized maximum slope held a significant relationship with the occurrence of anastomotic leakage (median of 0.081 versus 0.074, p = 0.32 and 0.041 vs 0.042, p = 0.51, respectively). Divergent approaches in maximum slope determination and raw signal filtering were identified as contributing factors to the differences in outcome. Conclusion This is the first study to demonstrate technical differences in software implementations that can lead to discrepancies in ICG-FA quantification in human clinical cases. The possible variation among software-based quantification methods should be considered when interpreting studies that report quantitative ICG-FA parameters and derived thresholds, as there may be a limited external validity.

Diseases of the EsophagusVol. 37(Supplement_1)
University of Copenhagen (DK), Copenhagen University Hospital (DK), Rigshospitalet (DK), Amsterdam University Medical Centers (NL), Cancer Center Amsterdam (NL), University of Amsterdam (NL)
Partnerships for the goals
Openalex Percentile: Top 73%
Esophageal Cancer Research and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.