Fatty Acid–Based pH‐Switchable Deep Eutectic Solvents for the Extraction and Preconcentration of Chlorobenzenes From Water Samples Followed by Gas Chromatography–Electron Capture Detection

ABSTRACT An easy, safe, simple, and efficient pH‐switchable hydrophobic deep eutectic solvent (DES)‐based liquid‐phase microextraction was developed for the extraction of chlorobenzenes (CBs) from water samples followed by a gas chromatography–electron capture detector (GC–ECD). The switchability of the synthesized DESs was tested by changing the pH. The DES synthesized from thymol:octanoic acid (OA) in a molar ratio of 2:1 had the highest efficiency in extracting CBs from water samples. 1,4‐Dibromobenzene was used as internal standard (IS). The optimal conditions were established to be 20.0 µL of thymol:OA (2:1), 100 µL of 5 mol L −1 KOH, 100 µL of 5 mol L −1 HCl, 60 s of extraction time, and without salt addition. Under the optimum conditions, the calibration graphs were linear in the range of 0.005–150 µg L −1 , and limits of detection were in the range of 0.001–0.03 µg L −1 . The relative standard deviations, including intraday and inter‐day for 5.0 µg L −1 of dichlorobenzene isomers, 2.0 µg L −1 of trichlorobenzene and tetrachlorobenzene isomers, and 0.50 µg L −1 of pentachlorobenzene and hexachlorobenzene isomers in water with using IS, were in the range of 0.6%–3.2% ( n = 7) and 3.8%–6.7% ( n = 7), respectively. The accuracies, including inter‐day and intraday, were in the range of 93.5%–106.3% and 91.7%–109.4%, respectively.

Authors

Institutions

Publication Details

Journal
Separation Science Plus
Published
2024-09-02
DOI
https://doi.org/10.1002/sscp.202400123
Citations
4
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fatty Acid–Based pH‐Switchable Deep Eutectic Solvents for the Extraction and Preconcentration of Chlorobenzenes From Water Samples Followed by Gas Chromatography–Electron Capture Detection

Fatemeh Hosseini, Mari Ataee, Nazir Fattahi, Touraj Ahmadi Jouybari et al.
4 citations
Separation Science Plus
Analytical Chemistry and Sensors
1.16
article

Fatty Acid–Based pH‐Switchable Deep Eutectic Solvents for the Extraction and Preconcentration of Chlorobenzenes From Water Samples Followed by Gas Chromatography–Electron Capture Detection

Fatemeh Hosseini, Mari Ataee, Nazir Fattahi, Touraj Ahmadi Jouybari, Hadi Ahmadi Jouybari
article en
4 citations

Abstract

ABSTRACT An easy, safe, simple, and efficient pH‐switchable hydrophobic deep eutectic solvent (DES)‐based liquid‐phase microextraction was developed for the extraction of chlorobenzenes (CBs) from water samples followed by a gas chromatography–electron capture detector (GC–ECD). The switchability of the synthesized DESs was tested by changing the pH. The DES synthesized from thymol:octanoic acid (OA) in a molar ratio of 2:1 had the highest efficiency in extracting CBs from water samples. 1,4‐Dibromobenzene was used as internal standard (IS). The optimal conditions were established to be 20.0 µL of thymol:OA (2:1), 100 µL of 5 mol L −1 KOH, 100 µL of 5 mol L −1 HCl, 60 s of extraction time, and without salt addition. Under the optimum conditions, the calibration graphs were linear in the range of 0.005–150 µg L −1 , and limits of detection were in the range of 0.001–0.03 µg L −1 . The relative standard deviations, including intraday and inter‐day for 5.0 µg L −1 of dichlorobenzene isomers, 2.0 µg L −1 of trichlorobenzene and tetrachlorobenzene isomers, and 0.50 µg L −1 of pentachlorobenzene and hexachlorobenzene isomers in water with using IS, were in the range of 0.6%–3.2% ( n = 7) and 3.8%–6.7% ( n = 7), respectively. The accuracies, including inter‐day and intraday, were in the range of 93.5%–106.3% and 91.7%–109.4%, respectively.

Separation Science PlusVol. 7(11)
Kermanshah University of Medical Sciences (IR), Babol University of Medical Sciences (IR)
Kermanshah University of Medical Sciences, Deputy for Research and Technology, Kermanshah University of Medical Sciences
Clean water and sanitation
Openalex Percentile: Top 25%
Analytical Chemistry and Sensors
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.