Assessment and Modeling of Workplace Exposure to Solar Ultraviolet Radiation in Makurdi, Nigeria

Solar radiation though beneficial to life but the harmful effects of over exposure especially in Nigeria has been neglected and its measurement/prediction has received negligible attention in the literature. This study measured and modeled workplace exposure to solar ultraviolet radiation (SUVR) in Makurdi, Benue State, Nigeria. Digital broadband meter was used to measure solar power density in three site while polymer Polysolphone dosimeters were fitted on a human manikin and placed in the sun between 10:00 am- 4:00pm (6 hours) to quantify the amount of Solar UVR absorbed by three occupational workers (Traders, Fishermen and Staff/Students). Five dosimeters were deployed in each of the three sites for calibration to measure UV absorbance in J/m2 while seven in each site were used for body parts. UV/VIS-spectrophotometer was handily used to measure both post and pre-absorbance and the UV exposures were calculated. The UV index was also calculated. Result shows that, head top had the highest exposure values 7.19kJ/m2, 6.51kJ/m2 and 7.00kJ/m2, while the least values was under cloth cover 2.47kJ/m2, 2.08kJ/m2 and 2.20kJ/m2 for traders, fishermen and staff/students respectively. Similarly, the calculated cumulative exposures were 3289.36kJ/m2, 497.82kJ/m2 and 1515.60kJ/m2 at the market square, river bank and the campus respectively. These values were higher than international ICNIRP average value 30J/m2. UV index at market square was 9 (media graphic colour purple), while at river bank and BSU campus was 8 (media graphic colour reddish). High mean irradiant values with high UV index indicates high risk of harm from unprotected sun exposure. Therefore, use of sun protective clothing is recommended and reduce time in the sun especially between 1:00pm and 2:00pm to prevent over exposure that will lead to serious harmful effects especially at the market place.

Authors

Institutions

Publication Details

Journal
Asian Journal of Research and Reviews in Physics
Published
2024-09-02
DOI
https://doi.org/10.9734/ajr2p/2024/v8i3169
Primary Topic
COVID-19 impact on air quality
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment and Modeling of Workplace Exposure to Solar Ultraviolet Radiation in Makurdi, Nigeria

Christopher Chiahemba Akoso, Samson Dauda Yusuf, T. C. Akpa
Asian Journal of Research and Reviews in Physics
COVID-19 impact on air quality
article

Assessment and Modeling of Workplace Exposure to Solar Ultraviolet Radiation in Makurdi, Nigeria

Christopher Chiahemba Akoso, Samson Dauda Yusuf, T. C. Akpa
article en

Abstract

Solar radiation though beneficial to life but the harmful effects of over exposure especially in Nigeria has been neglected and its measurement/prediction has received negligible attention in the literature. This study measured and modeled workplace exposure to solar ultraviolet radiation (SUVR) in Makurdi, Benue State, Nigeria. Digital broadband meter was used to measure solar power density in three site while polymer Polysolphone dosimeters were fitted on a human manikin and placed in the sun between 10:00 am- 4:00pm (6 hours) to quantify the amount of Solar UVR absorbed by three occupational workers (Traders, Fishermen and Staff/Students). Five dosimeters were deployed in each of the three sites for calibration to measure UV absorbance in J/m2 while seven in each site were used for body parts. UV/VIS-spectrophotometer was handily used to measure both post and pre-absorbance and the UV exposures were calculated. The UV index was also calculated. Result shows that, head top had the highest exposure values 7.19kJ/m2, 6.51kJ/m2 and 7.00kJ/m2, while the least values was under cloth cover 2.47kJ/m2, 2.08kJ/m2 and 2.20kJ/m2 for traders, fishermen and staff/students respectively. Similarly, the calculated cumulative exposures were 3289.36kJ/m2, 497.82kJ/m2 and 1515.60kJ/m2 at the market square, river bank and the campus respectively. These values were higher than international ICNIRP average value 30J/m2. UV index at market square was 9 (media graphic colour purple), while at river bank and BSU campus was 8 (media graphic colour reddish). High mean irradiant values with high UV index indicates high risk of harm from unprotected sun exposure. Therefore, use of sun protective clothing is recommended and reduce time in the sun especially between 1:00pm and 2:00pm to prevent over exposure that will lead to serious harmful effects especially at the market place.

Asian Journal of Research and Reviews in PhysicsVol. 8(3)
Nigeria Centre for Disease Control (NG)
Openalex Percentile: Top 87%
COVID-19 impact on air quality
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.