Numerical and experimental investigations of thermohydraulic performance enhancement of triangular duct solar air heaters using circular wing vortex generators

Abstract This study presents the thermohydraulic performance enhancement in a triangular duct solar air heater (TSAH) using circular wing vortex generators (CWVGs) on the absorber plate using computational fluid dynamics (CFD) methodology for the Reynolds number ( Re ) range of 6000–21,000. The use of wing vortex generators offers relatively lower interference with the core flow region, while the circular geometry offers a smooth curved edge, which reduces multiple vortex interactions in the wake region, thereby limiting the pressure drop. This study explores the impact of flow attack angle, longitudinal pitch, transverse pitch, and diameter of CWVG on the thermohydraulic performance of TSAH. The results reveal that a lower flow attack angle exhibits enhanced heat transfer with a lower friction factor penalty. The nondimensional diameter greater than d/D h = 0.325 tends to limit heat transfer and exhibits an increased friction factor. The transverse pitch parameter also exhibits a similar trend where the threshold nondimensional pitch is found to be 1.5. The highest improvement in Nu is 4.37 times that of smooth duct for d/D h = 0.433, P l /d = 1, P t /d = 1.5 and α = 20° at Re = 6000. The highest rise in friction factor is about 10.23 times that of smooth duct for d/D h = 0.433, P l /d = 1.0, P t /d = 1.5, and α = 20° at Re = 21,000. The highest thermohydraulic performance parameter (THPP) value is about 2.23 at Re = 6000, with THPP values ranging from 1.69 to 2.23 across different CWVG configurations. Finally, mathematical correlations are developed for Nu and friction factors which are in close agreement with CFD results, with deviations averaging 5.03% and 3.69%, respectively.

Authors

Institutions

Publication Details

Journal
Heat Transfer
Published
2024-09-02
DOI
https://doi.org/10.1002/htj.23167
Citations
4
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.85
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical and experimental investigations of thermohydraulic performance enhancement of triangular duct solar air heaters using circular wing vortex generators

N Madhwesh, M. S. Manjunath, G. K. Pramod, U.C. Arunachala
4 citations
Heat Transfer
Heat Transfer Mechanisms
0.85
article

Numerical and experimental investigations of thermohydraulic performance enhancement of triangular duct solar air heaters using circular wing vortex generators

N Madhwesh, M. S. Manjunath, G. K. Pramod, U.C. Arunachala
article en
4 citations

Abstract

Abstract This study presents the thermohydraulic performance enhancement in a triangular duct solar air heater (TSAH) using circular wing vortex generators (CWVGs) on the absorber plate using computational fluid dynamics (CFD) methodology for the Reynolds number ( Re ) range of 6000–21,000. The use of wing vortex generators offers relatively lower interference with the core flow region, while the circular geometry offers a smooth curved edge, which reduces multiple vortex interactions in the wake region, thereby limiting the pressure drop. This study explores the impact of flow attack angle, longitudinal pitch, transverse pitch, and diameter of CWVG on the thermohydraulic performance of TSAH. The results reveal that a lower flow attack angle exhibits enhanced heat transfer with a lower friction factor penalty. The nondimensional diameter greater than d/D h = 0.325 tends to limit heat transfer and exhibits an increased friction factor. The transverse pitch parameter also exhibits a similar trend where the threshold nondimensional pitch is found to be 1.5. The highest improvement in Nu is 4.37 times that of smooth duct for d/D h = 0.433, P l /d = 1, P t /d = 1.5 and α = 20° at Re = 6000. The highest rise in friction factor is about 10.23 times that of smooth duct for d/D h = 0.433, P l /d = 1.0, P t /d = 1.5, and α = 20° at Re = 21,000. The highest thermohydraulic performance parameter (THPP) value is about 2.23 at Re = 6000, with THPP values ranging from 1.69 to 2.23 across different CWVG configurations. Finally, mathematical correlations are developed for Nu and friction factors which are in close agreement with CFD results, with deviations averaging 5.03% and 3.69%, respectively.

Heat TransferVol. 54(1)
Manipal Academy of Higher Education (IN)
Affordable and clean energy
Openalex Percentile: Top 31%
Heat Transfer Mechanisms
0.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Numerical and experimental investigations of thermohydraulic performance enhancement of triangular duct solar air heaters using circular wing vortex generators — N Madhwesh, M. S. Manjunath, et al. · Heat Transfer (2024) | TGRS Research Map | TGRS