274. ROBOTIC REVISIONAL HIATAL HERNIA REPAIR (R-RHR): DOES IT MAKE SENSE?

Abstract Background The gastroesophageal reflux disease (GERD) is increasing among our population and Nissen Fundoplication still remains as the most widely performed technique. The robotic approach to the hiatal hernia repair has been proven to be safe and feasible. Precision and comfort seem to be some reasons that it makes, at least, comparable to the laparoscopic approach. Revisional hiatal hernia is a challenging situation to the operator due the adhesions and fibrosis of the tissues so our concern is that the best technology available is needed. Methods From June 2019 to November 2023 our division performed 14 cases of Robotic Revisional Hiatal Hernia Repair (R-RHR). Demographic items such as Gender, Age, Body Mass Index (BMI), Previous surgery, Time from first surgery and Postoperative outcomes as Operation Time, Length of stay (LOS), Mesh use, Complications and Readmissions were recorded. Results 10 women and 4 men were recruited. In all cases the DaVinci robotic platform X and Xi (Intuitive) was used. Mean age resulted in 63.5 years old (sd 12.25). Mean BMI was 26.97 (sd 3.52). In 71.4% cases the Previous HH Surgery was Nissen Fundoplication. 49.3 months was the mean time from the first surgery to the revisional procedure. 163.5 (sd 83.7) minutes was the mean operation time. Mean Lenght Of Stay resulted in 3.4 days (sd 1.4). There were no conversions to the laparoscopic approach. In 5 patients (35.8%) a mesh was placed. Pleural effusion was the only postoperative complication reported (1/14) and it was managed non-operatively. No other complications were recorded and mortality rate was 0. Conclusions To the authors knowledge, this is Spain’s largest Robotic - Revisional Hiatal Hernia Repair (R- RHR) series. The results lead us to conclude that the robotic approach, even the complexity of the surgery, is safe and feasible in trained teams with similar outcomes from the primary surgery that are published.

Authors

Institutions

Publication Details

Journal
Diseases of the Esophagus
Published
2024-09-01
DOI
https://doi.org/10.1093/dote/doae057.050
Primary Topic
Gastroesophageal reflux and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

274. ROBOTIC REVISIONAL HIATAL HERNIA REPAIR (R-RHR): DOES IT MAKE SENSE?

Arantxa Clavell Font, Elisenda Garsot, Ms Marta Viciano Martín, Christian Jose Herrero Vicente
Diseases of the Esophagus
Gastroesophageal reflux and treatments
article

274. ROBOTIC REVISIONAL HIATAL HERNIA REPAIR (R-RHR): DOES IT MAKE SENSE?

Arantxa Clavell Font, Elisenda Garsot, Ms Marta Viciano Martín, Christian Jose Herrero Vicente
article en

Abstract

Abstract Background The gastroesophageal reflux disease (GERD) is increasing among our population and Nissen Fundoplication still remains as the most widely performed technique. The robotic approach to the hiatal hernia repair has been proven to be safe and feasible. Precision and comfort seem to be some reasons that it makes, at least, comparable to the laparoscopic approach. Revisional hiatal hernia is a challenging situation to the operator due the adhesions and fibrosis of the tissues so our concern is that the best technology available is needed. Methods From June 2019 to November 2023 our division performed 14 cases of Robotic Revisional Hiatal Hernia Repair (R-RHR). Demographic items such as Gender, Age, Body Mass Index (BMI), Previous surgery, Time from first surgery and Postoperative outcomes as Operation Time, Length of stay (LOS), Mesh use, Complications and Readmissions were recorded. Results 10 women and 4 men were recruited. In all cases the DaVinci robotic platform X and Xi (Intuitive) was used. Mean age resulted in 63.5 years old (sd 12.25). Mean BMI was 26.97 (sd 3.52). In 71.4% cases the Previous HH Surgery was Nissen Fundoplication. 49.3 months was the mean time from the first surgery to the revisional procedure. 163.5 (sd 83.7) minutes was the mean operation time. Mean Lenght Of Stay resulted in 3.4 days (sd 1.4). There were no conversions to the laparoscopic approach. In 5 patients (35.8%) a mesh was placed. Pleural effusion was the only postoperative complication reported (1/14) and it was managed non-operatively. No other complications were recorded and mortality rate was 0. Conclusions To the authors knowledge, this is Spain’s largest Robotic - Revisional Hiatal Hernia Repair (R- RHR) series. The results lead us to conclude that the robotic approach, even the complexity of the surgery, is safe and feasible in trained teams with similar outcomes from the primary surgery that are published.

Diseases of the EsophagusVol. 37(Supplement_1)
Hospital Universitari Germans Trias i Pujol (ES)
Good health and well-being
Openalex Percentile: Top 74%
Gastroesophageal reflux and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.