777. COMBINED OESOPHAGEAL AND AIRWAY STENTING FOR MALIGNANT OESOPHAGEAL STRICTURES: THE UK’S LARGEST TERTIARY CENTRE EXPERIENCE AND DEVELOPMENT OF A NOVEL ALGORITHM

Abstract Background Malignant oesophageal strictures can cause airway compromise and fistula formation. Combined oesophageal and airway stenting is a potential treatment yet no guidelines exist. This study aims to describe the outcomes of same-session oesophageal and airway endoscopic stenting for malignant strictures and propose an algorithm for intervention. Methods A retrospective study on patients undergoing same-session gastroenterology (GI) and respiratory endoscopy at University College London Hospital, 2019-2023. All procedures were with anaesthetic-led propofol sedation. Endoscopic decision making was based on pre-procedure multidisciplinary team meeting (MDM) and intra-procedure clinical assessment. Data collected included malignancy type, luminal narrowing, complications, and mortality. Results 26 patients were identified. Mean age was 63 years. Cancer type was oesophageal (81%) or lung (19%). The most common referral indication was dysphagia (42%); airway compromise was often seen on imaging (65%). Stent insertion was oesophageal only (35%), airway only (19%) and dual (27%). Airway stenting was common (80%) if airway stenosis was >50%. No airway stenting occurred if stenosis was <50%. After oesophageal stenting, repeat bronchoscopy showed increased airway stenosis in 4 patients (25%). The only intraoperative complication was one oesophageal perforation. New tracheooesophageal fistula was the most common post-intervention complication (15%). Median time from malignancy diagnosis to death was 7.9 weeks. Conclusion We present the first algorithm (Figure 1) for endoscopic stenting in patients with malignant oesophageal stricture and airway involvement. We suggest upper GI and respiratory MDM to plan same-session endoscopy with decision-making framed by patient-centred goals given their poor prognosis.

Authors

Institutions

Publication Details

Journal
Diseases of the Esophagus
Published
2024-09-01
DOI
https://doi.org/10.1093/dote/doae057.375
Primary Topic
Esophageal and GI Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

777. COMBINED OESOPHAGEAL AND AIRWAY STENTING FOR MALIGNANT OESOPHAGEAL STRICTURES: THE UK’S LARGEST TERTIARY CENTRE EXPERIENCE AND DEVELOPMENT OF A NOVEL ALGORITHM

Nasar Aslam, Vinay Kumar Sehgal, Neal Navani, Monica Mullin et al.
Diseases of the Esophagus
Esophageal and GI Pathology
article

777. COMBINED OESOPHAGEAL AND AIRWAY STENTING FOR MALIGNANT OESOPHAGEAL STRICTURES: THE UK’S LARGEST TERTIARY CENTRE EXPERIENCE AND DEVELOPMENT OF A NOVEL ALGORITHM

Nasar Aslam, Vinay Kumar Sehgal, Neal Navani, Monica Mullin, Julian Gertner, David Yates Graham, Omer F. Ahmad, Ricky M. Thakrar, Rami Sweis, Matthew Banks, Ms Rosalind Shea
article en

Abstract

Abstract Background Malignant oesophageal strictures can cause airway compromise and fistula formation. Combined oesophageal and airway stenting is a potential treatment yet no guidelines exist. This study aims to describe the outcomes of same-session oesophageal and airway endoscopic stenting for malignant strictures and propose an algorithm for intervention. Methods A retrospective study on patients undergoing same-session gastroenterology (GI) and respiratory endoscopy at University College London Hospital, 2019-2023. All procedures were with anaesthetic-led propofol sedation. Endoscopic decision making was based on pre-procedure multidisciplinary team meeting (MDM) and intra-procedure clinical assessment. Data collected included malignancy type, luminal narrowing, complications, and mortality. Results 26 patients were identified. Mean age was 63 years. Cancer type was oesophageal (81%) or lung (19%). The most common referral indication was dysphagia (42%); airway compromise was often seen on imaging (65%). Stent insertion was oesophageal only (35%), airway only (19%) and dual (27%). Airway stenting was common (80%) if airway stenosis was >50%. No airway stenting occurred if stenosis was <50%. After oesophageal stenting, repeat bronchoscopy showed increased airway stenosis in 4 patients (25%). The only intraoperative complication was one oesophageal perforation. New tracheooesophageal fistula was the most common post-intervention complication (15%). Median time from malignancy diagnosis to death was 7.9 weeks. Conclusion We present the first algorithm (Figure 1) for endoscopic stenting in patients with malignant oesophageal stricture and airway involvement. We suggest upper GI and respiratory MDM to plan same-session endoscopy with decision-making framed by patient-centred goals given their poor prognosis.

Diseases of the EsophagusVol. 37(Supplement_1)
University College Hospital (GB), Wellcome / EPSRC Centre for Interventional and Surgical Sciences (GB), University College London (GB)
Good health and well-being
Openalex Percentile: Top 73%
Esophageal and GI Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.