Coupling Analysis of Safety Influencing Factors in Subway Station Operation under a High-Pressure Gas Pipeline

A subway station’s operation is susceptible to accidents when there is a high-pressure gas pipeline overlaying it, and analyzing the correlations between the safety influencing factors (SIFs) in this operating situation can provide paths to reduce safety accidents. Thus, this paper investigated the coupling correlations between the SIFs. We firstly identified the SIFs during subway station operation under a high-pressure pipeline (SSOUHP) based on a literature review and discussion with experts. Then, the analytic hierarchy process (AHP) and coupling degree analysis (CDA) were combined to assess the coupling correlations between the SIFs, and Y subway station was selected to test the proposed hybrid coupling analysis approach. Research results show that (a) 23 second-level SIFs were identified and these SIFs can be summed up into five first-level SIFs, namely, human-related SIFs, pipeline-related SIFs, station-related SIFs, environment-related SIFs, and management-related SIFs; (b) the proposed hybrid approach can be used to evaluate the coupling correlations between SIFs; (c) of the coupling situations during Y subway station’s operation, the internal coupling correlations among environment-related SIFs, the coupling correlations between pipe-related SIFs and environment-related SIFs, and the coupling correlations among human-related SIFs, pipe-related SIFs, and environment-related SIFs are all greater than 1, and the coordination degree is 0.778, 0.781, and 0.783, respectively, which is a high security risk; (d) the overall coupling degree among all SIFs during Y subway station’s operation is 0.995 and the coordination degree is 0.809, which is a low safety risk. The research can enrich knowledge in the safety evaluation area, and provide a reference for onsite safety management. The results are basically consistent with the conclusion of the enterprise report, which verifies the scientificity and validity of the evaluation method.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-08-31
DOI
https://doi.org/10.3390/buildings14092727
Primary Topic
Underground infrastructure and sustainability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coupling Analysis of Safety Influencing Factors in Subway Station Operation under a High-Pressure Gas Pipeline

Hujun Li, Jianhua Cheng, Wenrong Yan, Jiaqi Guo et al.
Buildings
Underground infrastructure and sustainability
article

Coupling Analysis of Safety Influencing Factors in Subway Station Operation under a High-Pressure Gas Pipeline

Hujun Li, Jianhua Cheng, Wenrong Yan, Jiaqi Guo, Linyu Li, Yingkang Weng
article en

Abstract

A subway station’s operation is susceptible to accidents when there is a high-pressure gas pipeline overlaying it, and analyzing the correlations between the safety influencing factors (SIFs) in this operating situation can provide paths to reduce safety accidents. Thus, this paper investigated the coupling correlations between the SIFs. We firstly identified the SIFs during subway station operation under a high-pressure pipeline (SSOUHP) based on a literature review and discussion with experts. Then, the analytic hierarchy process (AHP) and coupling degree analysis (CDA) were combined to assess the coupling correlations between the SIFs, and Y subway station was selected to test the proposed hybrid coupling analysis approach. Research results show that (a) 23 second-level SIFs were identified and these SIFs can be summed up into five first-level SIFs, namely, human-related SIFs, pipeline-related SIFs, station-related SIFs, environment-related SIFs, and management-related SIFs; (b) the proposed hybrid approach can be used to evaluate the coupling correlations between SIFs; (c) of the coupling situations during Y subway station’s operation, the internal coupling correlations among environment-related SIFs, the coupling correlations between pipe-related SIFs and environment-related SIFs, and the coupling correlations among human-related SIFs, pipe-related SIFs, and environment-related SIFs are all greater than 1, and the coordination degree is 0.778, 0.781, and 0.783, respectively, which is a high security risk; (d) the overall coupling degree among all SIFs during Y subway station’s operation is 0.995 and the coordination degree is 0.809, which is a low safety risk. The research can enrich knowledge in the safety evaluation area, and provide a reference for onsite safety management. The results are basically consistent with the conclusion of the enterprise report, which verifies the scientificity and validity of the evaluation method.

BuildingsVol. 14(9)
Guangzhou Metro Group (China) (CN), Henan Polytechnic University (CN)
National Natural Science Foundation of China, Henan Polytechnic University
Good health and well-being
Openalex Percentile: Top 85%
Underground infrastructure and sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.