Impact of Ventilator Settings on Pulmonary Nodule Localization Accuracy in a Hybrid Operating Room: A Single-Center Study

<b>Background:</b> Pulmonary nodule localization in a hybrid operating room (OR) followed by thoracoscopic operation presents a viable alternative for early lung cancer treatment, potentially supplanting conventional two-stage preoperative computed tomography-guided localization. This hybrid OR technique enables lesion localization under positive ventilation, contrasting with the traditional method requiring concurrent respiratory motion. This study aimed to evaluate our experience with different ventilator settings and the accuracy of pulmonary nodule localization. <b>Methods:</b> We retrospectively analyzed 176 patients with multiple pulmonary nodules who had localization procedures in our hybrid operating room. Ninety-five patients were assigned to the traditional ventilator setting group (tidal volume 8-10 mL/kg) and 81 to the lung-protective strategy group (tidal volume < 8 mL/kg). Localization accuracy was assessed via hybrid computed tomography imaging, ensuring that the needle-to-lesion distance was ≤5 mm. Between-group differences were assessed using the chi-squared test, Fisher's exact test, and the Mann-Whitney U test, as appropriate. <b>Results:</b> Pathological findings revealed primary lung malignancy in 150 patients, inclusive of invasive adenocarcinoma, adenocarcinoma in situ, and minimally invasive adenocarcinoma. Multivariate regression analysis identified tidal volume, nodule count, and localization depth as significant predictors of localization accuracy. <b>Conclusions:</b> This study demonstrated that ventilator settings with a tidal volume of 8-10 mL/kg significantly enhanced localization accuracy and slightly improved patient oxygenation. However, additional randomized controlled trials are warranted to validate these findings and establish definitive guidelines for future interventions.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-09-01
DOI
https://doi.org/10.3390/jcm13175183
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Ventilator Settings on Pulmonary Nodule Localization Accuracy in a Hybrid Operating Room: A Single-Center Study

Kwong‐Kwok Au, Yu-Hsiang Wang, Jiun Yi Hsia, Hsu Chih Huang et al.
Journal of Clinical Medicine
Lung Cancer Diagnosis and Treatment
article

Impact of Ventilator Settings on Pulmonary Nodule Localization Accuracy in a Hybrid Operating Room: A Single-Center Study

Kwong‐Kwok Au, Yu-Hsiang Wang, Jiun Yi Hsia, Hsu Chih Huang, Chih Yi Chen
article en

Abstract

<b>Background:</b> Pulmonary nodule localization in a hybrid operating room (OR) followed by thoracoscopic operation presents a viable alternative for early lung cancer treatment, potentially supplanting conventional two-stage preoperative computed tomography-guided localization. This hybrid OR technique enables lesion localization under positive ventilation, contrasting with the traditional method requiring concurrent respiratory motion. This study aimed to evaluate our experience with different ventilator settings and the accuracy of pulmonary nodule localization. <b>Methods:</b> We retrospectively analyzed 176 patients with multiple pulmonary nodules who had localization procedures in our hybrid operating room. Ninety-five patients were assigned to the traditional ventilator setting group (tidal volume 8-10 mL/kg) and 81 to the lung-protective strategy group (tidal volume < 8 mL/kg). Localization accuracy was assessed via hybrid computed tomography imaging, ensuring that the needle-to-lesion distance was ≤5 mm. Between-group differences were assessed using the chi-squared test, Fisher's exact test, and the Mann-Whitney U test, as appropriate. <b>Results:</b> Pathological findings revealed primary lung malignancy in 150 patients, inclusive of invasive adenocarcinoma, adenocarcinoma in situ, and minimally invasive adenocarcinoma. Multivariate regression analysis identified tidal volume, nodule count, and localization depth as significant predictors of localization accuracy. <b>Conclusions:</b> This study demonstrated that ventilator settings with a tidal volume of 8-10 mL/kg significantly enhanced localization accuracy and slightly improved patient oxygenation. However, additional randomized controlled trials are warranted to validate these findings and establish definitive guidelines for future interventions.

Journal of Clinical MedicineVol. 13(17)
Chung Shan Medical University Hospital (TW), Chung Shan Medical University (TW)
Good health and well-being
Openalex Percentile: Top 74%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.