Accurate Measurement of Tower Grounding Resistance for Single-Tower and Multi-Tower Parallel Scenarios Based on the Clamp Meter Method: For the Sustainable Operation of Towers

Transmission tower grounding safety is a critical element that significantly impacts the reliability and sustainability of power grids. Tower grounding resistance is a significant grounding characteristic parameter. In order to accurately measure the grounding resistance of towers using the clamp meter method in both single-tower and multi-tower parallel scenarios, this paper establishes theoretical calculation models for measuring tower grounding resistance using the clamp meter method. Considering the interaction between the artificial grounding device and the tower foundation, this paper models and simulates transmission towers and lightning shield wires, analyzing the influencing factors on the grounding resistance measurement results using the clamp meter method in both single- and multi-tower parallel scenarios. The results show that for single towers, the clamp meter measurement results increase with decreasing foundation root spacing and increasing length of the artificial device’s extension lines, but the changes are relatively small. In multi-tower grounding scenarios, due to the shunting effect of the parallel branches formed by the towers and lightning shield wires, the value is smaller than in single-tower grounding scenarios. Changing the number of parallel towers and the type of lightning shield wire produces little effect on the measurement results. However, changes in soil resistivity have the most significant impact. Therefore, correction formulas for the impact of soil resistivity on clamp meter measurements are proposed and then verified by applying them to field tests.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2024-08-31
DOI
https://doi.org/10.3390/su16177551
Citations
3
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate Measurement of Tower Grounding Resistance for Single-Tower and Multi-Tower Parallel Scenarios Based on the Clamp Meter Method: For the Sustainable Operation of Towers

Kaiwen Feng, Zoujun Wang, Y. H. Zhang, Yirui Zhang et al.
3 citations
Sustainability
Structural Health Monitoring Techniques
0.78
article

Accurate Measurement of Tower Grounding Resistance for Single-Tower and Multi-Tower Parallel Scenarios Based on the Clamp Meter Method: For the Sustainable Operation of Towers

Kaiwen Feng, Zoujun Wang, Y. H. Zhang, Yirui Zhang, Hailiang Lu, Zhihui Zheng, Zhitong Tian
article en
3 citations

Abstract

Transmission tower grounding safety is a critical element that significantly impacts the reliability and sustainability of power grids. Tower grounding resistance is a significant grounding characteristic parameter. In order to accurately measure the grounding resistance of towers using the clamp meter method in both single-tower and multi-tower parallel scenarios, this paper establishes theoretical calculation models for measuring tower grounding resistance using the clamp meter method. Considering the interaction between the artificial grounding device and the tower foundation, this paper models and simulates transmission towers and lightning shield wires, analyzing the influencing factors on the grounding resistance measurement results using the clamp meter method in both single- and multi-tower parallel scenarios. The results show that for single towers, the clamp meter measurement results increase with decreasing foundation root spacing and increasing length of the artificial device’s extension lines, but the changes are relatively small. In multi-tower grounding scenarios, due to the shunting effect of the parallel branches formed by the towers and lightning shield wires, the value is smaller than in single-tower grounding scenarios. Changing the number of parallel towers and the type of lightning shield wire produces little effect on the measurement results. However, changes in soil resistivity have the most significant impact. Therefore, correction formulas for the impact of soil resistivity on clamp meter measurements are proposed and then verified by applying them to field tests.

SustainabilityVol. 16(17)
Wuhan University (CN), Wuhan Research Institute of Materials Protection (CN), Hunan Xiangdian Test Research Institute (China) (CN)
Life in Land
Openalex Percentile: Top 30%
Structural Health Monitoring Techniques
0.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.