Effects of High Temperature and High Humidity on the Degree of Ocular Damage Caused by 60 GHz Millimeter Wave Exposure

Millimeter waves (MMW) are pervasive in society; however, studies on the biological effects of MMW exposure are usually performed in laboratory settings not reflecting global environmental diversity. We investigated the effects of a 6-min exposure to 60 GHz MMW (wavelength, 5.0 mm) at incident power densities of 200 and 300 mW cm -2 in eyes (exposed right eyes vs. unexposed left eyes) under various ambient temperature/relative humidity environments (24 °C/50%, 45 °C/20%, and 45 °C/80%) using an in vivo rabbit model. Correlations were examined with adverse ocular events, including corneal epithelial damage (assessed using fluorescein staining), corneal opacity (evaluated by slit-lamp microscopy), and corneal thickness (measured via optical coherence tomography). Our findings indicate that higher temperatures and humidity tend to exacerbate MMW-induced ocular damage, albeit not significantly in the present study. Further research with a larger sample size is warranted. Incident power density emerged as a factor that was directly linked to the ocular damage threshold. High ambient temperature and humidity tended to exacerbate ocular damage from MMW exposure, although the effect was secondary. Ocular damage in a high-temperature (45 °C), high-humidity (80%) environment was increased to the same extent as that by incident power density increased by approximately 100 mW cm -2 in an ocular damage model in a standard environment (24 °C, 50%). In a high-humidity environment, the internal ocular tissue temperature increased at a high ambient temperature of 45 °C, suggesting that the eyeball may respond differently compared to other tissues.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2024-08-30
DOI
https://doi.org/10.1097/hp.0000000000001843
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of High Temperature and High Humidity on the Degree of Ocular Damage Caused by 60 GHz Millimeter Wave Exposure

Masami Kojima, Aki Hada, Yukihisa Suzuki, Masateru Ikehata et al.
1 citations
Health Physics
Non-Invasive Vital Sign Monitoring
0.18
article

Effects of High Temperature and High Humidity on the Degree of Ocular Damage Caused by 60 GHz Millimeter Wave Exposure

Masami Kojima, Aki Hada, Yukihisa Suzuki, Masateru Ikehata, Hiroshi Sasaki, Takafumi Tasaki, Toshio Kamijo
article en
1 citations

Abstract

Millimeter waves (MMW) are pervasive in society; however, studies on the biological effects of MMW exposure are usually performed in laboratory settings not reflecting global environmental diversity. We investigated the effects of a 6-min exposure to 60 GHz MMW (wavelength, 5.0 mm) at incident power densities of 200 and 300 mW cm -2 in eyes (exposed right eyes vs. unexposed left eyes) under various ambient temperature/relative humidity environments (24 °C/50%, 45 °C/20%, and 45 °C/80%) using an in vivo rabbit model. Correlations were examined with adverse ocular events, including corneal epithelial damage (assessed using fluorescein staining), corneal opacity (evaluated by slit-lamp microscopy), and corneal thickness (measured via optical coherence tomography). Our findings indicate that higher temperatures and humidity tend to exacerbate MMW-induced ocular damage, albeit not significantly in the present study. Further research with a larger sample size is warranted. Incident power density emerged as a factor that was directly linked to the ocular damage threshold. High ambient temperature and humidity tended to exacerbate ocular damage from MMW exposure, although the effect was secondary. Ocular damage in a high-temperature (45 °C), high-humidity (80%) environment was increased to the same extent as that by incident power density increased by approximately 100 mW cm -2 in an ocular damage model in a standard environment (24 °C, 50%). In a high-humidity environment, the internal ocular tissue temperature increased at a high ambient temperature of 45 °C, suggesting that the eyeball may respond differently compared to other tissues.

Health PhysicsVol. 127(5)
Railway Technical Research Institute (JP), Kanazawa Medical University (JP), Kanazawa Medical University Hospital (JP), Tokyo Metropolitan University (JP)
Life in Land
Openalex Percentile: Top 53%
Non-Invasive Vital Sign Monitoring
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.