Lessons learned: drive-through COVID-19 clinic testing during an adaptive epidemic response and a point-of-care test assessment of a computer-read rapid lateral flow immunoassay with fluorescence-based detection

<b>Background.</b> The COVID-19 pandemic demonstrated a need for robust SARS-CoV-2 test evaluation infrastructure to underpin biosecurity and protect the population during a pandemic health emergency.<b>Gap statement.</b> The first generation of rapid antigen tests was less accurate than molecular methods due to their inherent sensitivity and specificity shortfalls, compounded by the consequences of self-testing. This created a need for more accurate point-of-care SARS-CoV-2 detection methods.<b>Aim.</b> Here we present the lessons-learned during the COVID-19 emergency response in Western Australia including the detailed set-up, evaluation and operation of rapid antigen test in a state-run drive-through sample collection service during the COVID-19 pandemic after the strict border shutdown ended.<b>Methods.</b> We report a conformity assessment of a novel, second-generation rapid antigen test (Virulizer) comprising a technician-operated rapid lateral flow immunoassay with fluorescence-based detection.<b>Results.</b> The Virulizer rapid antigen test demonstrated up to 100% sensitivity (95% CI: 61.0-100%), 91.94% specificity (95% CI: 82.5-96.5%) and 92.65% accuracy when compared to a commercial PCR assay method. Wide confidence intervals in our series reflect the limits of small sample size. Nevertheless, the Virulizer assay performance was well-suited to point-of-care screening for SARS-CoV-2 in a drive-through clinic setting.<b>Conclusion.</b> The adaptive evaluation process necessary under changing pandemic conditions enabled assessment of a simple sample collection and point-of-care testing process, and showed how this system could be rapidly deployed for SARS-CoV-2 testing, including to regional and remote settings.

Authors

Institutions

Publication Details

Journal
Journal of Medical Microbiology
Published
2024-09-02
DOI
https://doi.org/10.1099/jmm.0.001875
Citations
3
Primary Topic
SARS-CoV-2 detection and testing
Type
article
Field-Weighted Citation Impact
1.17

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lessons learned: drive-through COVID-19 clinic testing during an adaptive epidemic response and a point-of-care test assessment of a computer-read rapid lateral flow immunoassay with fluorescence-based detection

Aus Molan, Rebecca Wake, Courtney Jeffery, Todd M. Pryce et al.
3 citations
Journal of Medical Microbiology
SARS-CoV-2 detection and testing
1.17
article

Lessons learned: drive-through COVID-19 clinic testing during an adaptive epidemic response and a point-of-care test assessment of a computer-read rapid lateral flow immunoassay with fluorescence-based detection

Aus Molan, Rebecca Wake, Courtney Jeffery, Todd M. Pryce, Leah Rankine-Wilson, Teagan Paton, Teresa Oncken, Irshan Basrewan, Tim Inglis
article en
3 citations

Abstract

<b>Background.</b> The COVID-19 pandemic demonstrated a need for robust SARS-CoV-2 test evaluation infrastructure to underpin biosecurity and protect the population during a pandemic health emergency.<b>Gap statement.</b> The first generation of rapid antigen tests was less accurate than molecular methods due to their inherent sensitivity and specificity shortfalls, compounded by the consequences of self-testing. This created a need for more accurate point-of-care SARS-CoV-2 detection methods.<b>Aim.</b> Here we present the lessons-learned during the COVID-19 emergency response in Western Australia including the detailed set-up, evaluation and operation of rapid antigen test in a state-run drive-through sample collection service during the COVID-19 pandemic after the strict border shutdown ended.<b>Methods.</b> We report a conformity assessment of a novel, second-generation rapid antigen test (Virulizer) comprising a technician-operated rapid lateral flow immunoassay with fluorescence-based detection.<b>Results.</b> The Virulizer rapid antigen test demonstrated up to 100% sensitivity (95% CI: 61.0-100%), 91.94% specificity (95% CI: 82.5-96.5%) and 92.65% accuracy when compared to a commercial PCR assay method. Wide confidence intervals in our series reflect the limits of small sample size. Nevertheless, the Virulizer assay performance was well-suited to point-of-care screening for SARS-CoV-2 in a drive-through clinic setting.<b>Conclusion.</b> The adaptive evaluation process necessary under changing pandemic conditions enabled assessment of a simple sample collection and point-of-care testing process, and showed how this system could be rapidly deployed for SARS-CoV-2 testing, including to regional and remote settings.

Journal of Medical MicrobiologyVol. 73(9)
Edith Cowan University (AU), University of British Columbia (CA), The University of Western Australia (AU), Curtin University (AU), Harry Perkins Institute of Medical Research (AU), Fiona Stanley Hospital (AU), WA Country Health Service (AU), Pathwest Laboratory Medicine (AU)
Government of Western Australia, Fiona Stanley Hospital, Medical Research Council, National Health and Medical Research Council
Good health and well-being
Openalex Percentile: Top 22%
SARS-CoV-2 detection and testing
1.17
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.